22
d) Tension adjustment of the take-up lever spring
If you unfasten the nut
①
in the thread-adjusting device shaft and turn it clockwise at the face groove of the thread-adjusting device
shaft
②
using a screwdriver, the tension of the take-up lever spring
③
will become stronger, and weaker when turned counterclockwise.
e) Timing adjustment of the take-up lever spring
If you loosen the stopper screw
④
and move the guide plate
⑤
of the take-up lever spring in a clockwise direction, the operating timing
of the take-up lever spring
③
will become faster, and slower when turned counterclockwise.
※
The standard operating timing of the take-up lever spring is when the stopper screw
④
comes to position at the center of the guide plate
⑤
.
[ Fig. 30 ]
[ Fig. 31 ]
①
②
③
④
⑤
③
Weak
Strong
c) Adjustment of the take-up lever spring
If you loosen the stopper clamp screw
①
and turn the take-up lever spring stopper
②
counterclockwise as shown in [Figure 29], the
moving range of the take-up lever spring
③
will become larger, and when turned clockwise, smaller.
※
The standard moving range of the take-up lever spring is 5~10 mm.
[ Fig. 29 ]
①
②
③
③