15
Press[2]:Main unit stops alarming and Disarm; it stops calling users.
Press[3]:Siren off and monitors the scene for 30 seconds; for continued monitoring, press [3] again
to monitor for another 30 seconds
Press[4]:Main unit starts a 30-second two-way intercom It cannot be controlled the mobile during
the time of intercom
5. Remote Control
Dial the number associated to the alarm main unit by phone (mobile phone), and after the ringing
cycle, you can hear a voice prompt “Please inter password (default: 1234)”.If the password is right,
you will here “Press Enter induction”. Press 1 to arm, Press 2 to disarm, Press 3 to monitor, Press 4
to intercom. If the password is wrong, you will hear a prompt voice “wrong password, please
re-enter”,
Press[1]: arm, if finished successfully, you will hear a voice prompt “System armed”.
Press[2]: disarm, if finished successfully, you will hear a voice prompt “System disarmed”.
Press[3]:monitoring for 30 seconds, to continue monitoring. Press [3] again to monitor
foranother30 seconds
Press[4]:two-way intercom for 30 seconds. You can’t operate the main unit during this time.
6. Emergency help
Sometimes, there may be some accidents happening (such as sudden illness of old people or
children, fire accident, burglar intrusion).Press [SOS] button on keypad, or [ ] button on the
remote controller or wireless panic button, the main unit will alarm and make call to the preset user
numbers.
Remote controller operation: press [ ] button on the remote controller.
Main panel operation: press [SOS].
The SMS content for emergency help is: 00 zone SOS alarm.
7. System Dialing Function
In disarm status, you can use the main unit to make any call just like a land-line telephone. Dial
telephone number on keypad, press [
] button, the main unit will make a beep and the LCD
screen will display the number you are calling. After the call, press [ ] button again, the call will
be hanged up and main unit will be in disarm status.
8. Alarming Record Checking
This alarm system can store 200 alarm records. The last alarm is ranked as the first record. And
when the record number exceeds 200, the most previous record will be deleted automatically.
Checking method: In disarm state, input [00] + status “ok”, the main unit enters the state of alarm
record checking. Press “4” or “6” to upturn or downturn, and press “ESC” to exit checking.
Fig1: press “00” in disarm status Fig2: press “4” or “6 “to check Fig3: press “4 ”or “ 6” to check
Chapter6. Technical Parameters
Input Voltage: DC12V/1A
Standby Current: <40mA
Alarming Current: <450Ma
Wireless Frequency: 433/315MHZ EV1527
GSM Frequency: 850/900/1800/1900MHZ
Back-up Battery: Lithium ion rechargeable battery
Siren Volume: 100-110Db
Chapter7. Components List
Main panel
1pc
Remote controller
2pc