3
mode
2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will
set the curtain motor controller into inclusion mode. 6 seconds timeout if there is no reply from the Z-Wave
primary controller, repeat the operation.
3. The curtain motor controller will be added to the Z-Wave network.
Exclusion (removing from a Z-Wave network)
1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers
manual on how to set your controller into exclusion).
2. Power on the curtain motor controller and set it into exclusion mode. There are two methods to set the
curtain motor controller into exclusion mode:
1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into exclusion
mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will
set the curtain motor controller into exclusion mode. 6 seconds timeout if there is no reply from the Z-
Wave primary controller, repeat the operation.
3. The curtain motor controller will be removed from the Z-Wave network.
Factory Reset
Press and hold down network inclusion/exclusion button for over 10 seconds, the curtain motor controller
will be reset to factory defaults.
Configure Parameter 3 to Set Working Mode
1. When parameter 3 value is configured as 0, light mode: either S1 or S2 can control both Q1 and Q2,
short pressing or holding down will be recognized automatically. For detailed configuration please refer to
configuration parameter 7.
Note
: when configured as light mode, endpoint 1 reflects to relay 1 (Q1), endpoint 2 reflects to relay 2
(Q2).
2. When parameter 3 value is configured as 1, shutter mode without positioning: S1 and S2 are only valid
while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1
(Q1) OFF.
3. When parameter 3 value is configured as 2, shutter mode with positioning: S1 and S2 are only valid
while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1
(Q1) OFF. When reaching any end’s positioning, both relays will be OFF.
4. When parameter 3 value is configured as 3, venetian mode (up/down and slats rotation): Hold down S1,
relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. When reaching any
end’s positioning, both relays will be OFF. This mode supports shutter dim command, which means it
supports the secondary switch of command class SWITCH_MULTILEVEL_START_LEVEL_CHANGE.
Positioning Calibration
Calibration is a process during which a curtain motor controller learns the position of the limit switches
and a motor characteristic. Calibration is mandatory when the working mode of the curtain motor
controller is Shutter mode with positioning and venetian mode (up/down and slat rotation).Connect the
controller to the motor according to wiring diagram, there are two calibration methods as follows:
. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.