background image

3

mode

2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will 
set the curtain motor controller into inclusion mode. 6 seconds timeout if there is no reply from the Z-Wave 
primary controller, repeat the operation.

3. The curtain motor controller will be added to the Z-Wave network.

Exclusion (removing from a Z-Wave network)

1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers 
manual on how to set your controller into exclusion).

2. Power on the curtain motor controller and set it into exclusion mode. There are two methods to set the 
curtain motor controller into exclusion mode:

1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into exclusion 
mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.

2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will 
set the curtain motor controller into exclusion mode. 6 seconds timeout if there is no reply from the Z-
Wave primary controller, repeat the operation.

3. The curtain motor controller will be removed from the Z-Wave network.

Factory Reset 

Press and hold down network inclusion/exclusion button for over 10 seconds, the curtain motor controller 
will be reset to factory defaults.

Configure Parameter 3 to Set Working Mode

1. When parameter 3 value is configured as 0, light mode: either S1 or S2 can control both Q1 and Q2, 
short pressing or holding down will be recognized automatically. For detailed configuration please refer to 
configuration parameter 7.

Note

: when configured as light mode, endpoint 1 reflects to relay 1 (Q1), endpoint 2 reflects to relay 2 

(Q2).

2. When parameter 3 value is configured as 1, shutter mode without positioning: S1 and S2 are only valid 
while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 
(Q1) OFF.

3. When parameter 3 value is configured as 2, shutter mode with positioning: S1 and S2 are only valid 
while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 
(Q1) OFF. When reaching any end’s positioning, both relays will be OFF.

4. When parameter 3 value is configured as 3, venetian mode (up/down and slats rotation): Hold down S1, 
relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. When reaching any 
end’s positioning, both relays will be OFF. This mode supports shutter dim command, which means it 
supports the secondary switch of command class SWITCH_MULTILEVEL_START_LEVEL_CHANGE.

Positioning Calibration

Calibration is a process during which a curtain motor controller learns the position of the limit switches 
and a motor characteristic. Calibration is mandatory when the working mode of the curtain motor 
controller is Shutter mode with positioning and venetian mode (up/down and slat rotation).Connect the 
controller to the motor according to wiring diagram, there are two calibration methods as follows:

. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.

Summary of Contents for SR-ZV9080A-B

Page 1: ...netian blind slats Precise positioning is available for the motors equipped with mechanic and electronic end switches The device also allows for controlling on off of lights The module may be controlled wirelessly through the Z Wave network primary controller or through the switch keys connected to it In addition the curtain motor controller is equipped with Power Metering and over current protect...

Page 2: ...ary or toggle switches and by dedicated roller blind control switches Connected motor s current and historical power consumption measured Over current protection To be installed in wall switch boxes of dimensions allowing for installation conforming to provisions of applicable regulations The curtain motor controller supports OTA and can update firmware wirelessly Installation Guide Please read ca...

Page 3: ...s 0 light mode either S1 or S2 can control both Q1 and Q2 short pressing or holding down will be recognized automatically For detailed configuration please refer to configuration parameter 7 Note when configured as light mode endpoint 1 reflects to relay 1 Q1 endpoint 2 reflects to relay 2 Q2 2 When parameter 3 value is configured as 1 shutter mode without positioning S1 and S2 are only valid whil...

Page 4: ...ibute supported by switch S1 and S2 are as follows Default configuration of CENTRAL_SCENE_CONFIGURATION_SET is Slow Refresh 1 send Key Held Down every 55s when the switch is pressed and held down Association Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device n...

Page 5: ...curtain motor controller is set to inclusion exclusion mode again it will send out Node Information Frame there are 2 kinds of operation as follows 1 triple press the K2 button the curtain motor controller will be set to inclusion exclusion mode then send out Node Information Frame 2 When the curtain motor controller is under inclusion mode there are two kinds of operation 1 Triple press K2 button...

Page 6: ...lave AOS SUPPORTED COMMAND CLASS Node Info COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SECURITY V2 V2 V1 V1 Endpoint 1 device type GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Endpoint 2 device type GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Root Device Command List Support S2 S0 COMMAND_CLASS_SUPERVISI...

Page 7: ... 2 Command List Support S2 S0 COMMAND_CLASS_SUPERVISION V1 COMMAND_CLASS_SWITCH_BINARY V1 YES COMMAND_CLASS_ASSOCIATION V2 YES COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 YES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION V3 YES COMMAND_CLASS_SCENE_ACTIVATION V1 YES COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 YES COMMAND_CLASS_SCENE_ACTIVATION V1 YES COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 YES COMMAND_CLASS_MULTI_CHANNE...

Page 8: ...es both 0 and 99 When the working mode is configured as light mode as long as the state changes the state change percentage threshold will be reported SWITCH_MULTILEVEL_REPORT 0 disable to report actively 1 10 value to report unit is one percent 0x02 2 1 1 Enable disable over current protection 0 disable 1 enable when over current detected there are two methods to cancel alarm 1 short press either...

Page 9: ... switch OFF Q2 When S1 short pressed not processed Press and hold down S2 to switch ON Q2 then release to switch OFF Q2 When S2 short pressed not processed Value 3 Short press S1 or S2 to switch ON OFF of both Q1 and Q2 simultaneously When S1 or S2 pressed and held down not processed Value 4 Press and hold down S1 to switch ON Q1 and Q2 When S1 short pressed not processed Press and hold down S2 to...

Page 10: ...shold function 1 10 value of the current change absolute threshold if current change value is over the threshold value report the current change value using METER_REPORT 0x0B 11 0x0C 12 Voltage change absolute threshold unit is 1V 0 disable absolute threshold function 1 10 value of the voltage change absolute threshold if voltage change value is over the threshold value report the voltage change v...

Page 11: ...own and slats rotation K2 inclusion exclusion button used to add or remove a device from the system Compatible Load Types Supported load types 100 240V Lamp and resistive loads Inductive loads Max 4A Max 2A Capacitive loads Max 2A 1 15 1 5S 0x0d 13 Slats rotation time unit is 0 1S 0 disable the function 5 250 0 5S 25S value of the slats rotation time This parameter is only valid when parameter 3 i...

Page 12: ...100 240V S 2 Curtain Motor SR ZV9080A B 908 42MHz Made in China S 1 Q2 Controller MAX 2A S2 S1 1 Curtain Motor Connection Diagram DOWN UP Neutral Live Ratings 120V 60Hz MAX 4A FCC ID XXXSR9080A K1 K2 L Q1 N N AC 100 240V S 2 Curtain Motor SR ZV9080A B 908 42MHz Made in China S 1 Q2 Controller MAX 2A S2 S1 12 ...

Reviews: