11
Wiring Diagram
Notes for the diagrams:
L - terminal for live lead
N - terminal for neutral lead
S1 - terminal for switch key No. 1 (enable to set the device into inclusion/exclusion mode)
S2 - terminal for switch key No. 2
Q1 - output terminal no. 1 for electrical motor
Q2 - output terminal no. 2 for electrical motor
K1 - positioning calibration button when working mode is configured as shutter mode with
positioning or venetian mode (up/down and slats rotation)
K2 - inclusion/exclusion button (used to add or remove a device from the system)
Compatible Load Types
Supported load types
100-240V~
Lamp and resistive loads
Inductive loads
Max. 4A
Max. 2A
Capacitive loads
Max. 2A
1
15 (1.5S)
0x0d(13)
Slats rotation time, unit is 0.1S
0: disable the function
5-250 (0.5S-25S): value of the slats rotation time
This parameter is only valid when parameter 3 is
configured as venetian mode (up/down and slats
rotation).
4
3600 (1 hour)
0x0E(14)
Time cycle to report the values of energy
consumption, voltage, current and load power
actively
60-2678400 (31 days), value of the time cycle,
unit is S
.