Sunricher SR-ZV9002T4-CCT-EU Instructions Download Page 3

Choose the objects you would like to control:

• 

Short press Group number button 1, all associated devices of Association Group 2 are the objects which the 

command will be sent to.

• 

Short press Group number button 2, all associated devices of Association Group 3 are the objects which the 

command will be sent to.

• 

Short press Group number button 3, all associated devices of Association Group 4 are the objects which the 

command will be sent to.

• 

Short press Group number button 4, all associated devices of Association Group 5 are the objects which the 

command will be sent to.

Control the objects you would like to control:

• 

Double click Group number button 1-4, activation of scenes in Gateways using Command Class Central 

Scene.

• 

Short press Scene button S1/S2/S3/S4, direct control of associated devices using Scene Activation Set, 

Scene ID = 0x10 / 0x20 / 0x30 / 0x40 to the last used Group 2, 3, 4 or 5.

• 

Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, 

Scene ID = 0x10 / 0x20 / 0x30 / 0x40 to the last used Group 2, 3, 4 or 5.

• 

Short press “ALL ON/OFF” button, direct control of associated devices using Basic Set On/Off commands.

• 

Short touch or slide touch the “Color Wheel”, direct control of associated devices using Color Switch Set 

commands.

• 

Press and hold down brightness down and brightness up buttons, direct control of associated devices using 

Multilevel Switch Start Level Change Set commands.

Node Information Frame 

The Node Information Frame is the business card of a Z-Wave device. It contains information about the device 
type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a 
Node Information Frame. Beside this it may be needed for certain network operations to send out a Node 
Information Frame.  

How to send out Node Information Frame:

Manufacturer Specific

Parameter 

Manufacturer ID 

Product Type ID 

Product ID 

Value (hex) 

0x0330

0x0300

0xa103

SUPPORTED COMMAND CLASS

Node Info

V2

V1

V1

V2

V1

V4

V3

COMMAND_CLASS_ZWAVEPLUS_INFO

COMMAND_CLASS_SECURITY

COMMAND_CLASS_SECURITY_2

COMMAND_CLASS_TRANSPORT_SERVICE

COMMAND_CLASS_SUPERVISION

COMMAND_CLASS_SWITCH_MULTILEVEL

COMMAND_CLASS_SWITCH_COLOR

Support S2

To remove all associated devices in an association group on the wall controller directly:

1. Press and hold down “ALL ON/OFF” button on the wall controller for over 3 seconds, LED indicator turns on.

2. Click any Group number button on the wall controller 5 times continuously within 25 seconds to remove all 
associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are 
removed successfully.

4 Groups

Decrease whole brightness

Increase whole brightness

Save and recall 4 scenes

ALL ON/OFF button, broadcast to turn on/off all

Color Wheel for adjusting relative brightness

between  PWM1 and PWM2

50% PWM1 +50% PWM2

100% PWM1 + 0% PWM2

0% PWM1 + 100% PWM2

IP Rating

Frequency 

SDK

Explorer Frame Support

Device Type

Generic Device Class

Specific Device Class

Routing 

FLiRS 

IP 20

868.42 MHz (EU)

Up to 100 m outside, on average up to 

40 m inside buildings

6.71.01

Yes

Wall Controller

Wall Controller

Basic Wall Controller

Yes

No

Wireless Range

Z-Wave Plus Info 

Parameter 

Z-Wave Plus Version  

Role Type  

Node Type  

Installer Icon Type

User Icon Type

Value 

Slave Always On

ZWAVEPLUS

0x1600 (ICON_TYPE_GENERIC_WALL_CONTROLLER) 

0x1600 (ICON_TYPE_GENERIC_WALL_CONTROLLER) 

Set the wall controller into inclusion/exclusion mode: press and hold down “ALL ON/OFF” button for over 3 
seconds, or short press the “inclusion/exclusion” button, LED indicator turns on to indicate the wall controller 
has already sent out Node Information Frame, the user can repeat the operation to set the wall controller to quit 
“inclusion/exclusion mode”.

Technical Data