Sunricher SR-ZV9002T4-CCT-EU Instructions Download Page 2

how to set your controller into exclusion).

2. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 
seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns 
on and shows 3 short blinks and 1 long blink to indicate successful exclusion.

Once the wall controller quits “exclusion mode”, the LED indicator will turns off. There are 3 methods for the 
wall controller to quit “exclusion mode”:

1. Automatically quits after successful exclusion.
2. Quits after 25 seconds timeout.
3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the “inclusion/exclusion” 
button to quit.

Method 2: Factory reset the wall controller will force the wall controller to be excluded from a network. (please 
refer to the part “Factory Reset” of this manual)

Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary 
controller/gateway is missing or otherwise inoperable.

How to check whether the wall controller already included to a network

Operate any button to check if there is indication from the LED indicator, and no LED indication means the wall 
controller does not belong to any network.

If the wall controller already belongs to a network, follow the exclusion process before including it in your 
network. Otherwise inclusion of this device will fail.

Factory Reset 

Press and hold down “inclusion/exclusion” button for over 8 seconds, LED indicator will blink slowly to indicate 
successful factory reset, release “inclusion/exclusion” button, the wall controller will restart automatically.

Association

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device 
is called association. In order to control a different device, the controlling device needs to maintain a list of 
devices that will receive controlling commands. These lists are called association groups and they are always 
related to certain events (e.g. button pressed). In case the event happens all devices stored in the respective 
association group will receive a common wireless command.

Association Groups: 

Each group supports maximum 12 nodes for association, the same device can be associated with multiple 
groups on the wall controller simultaneously, to ensure better control experience, the wall controller shall 
remove the associated devices that are not under working status from association groups in time.

Set and unset associations:

 (Note: All association information will be cleared automatically once the wall controller is excluded from a 
network.)

Associations can be assigned and remove either via Z-Wave commands or using the device itself.

1. Set association by operating primary controller/gateway to send packets to the wall controller:

The primary controller/gateway sends packets to the wall controller using “Command Class ASSOCIATION” or 
“Command Class Multi Channel Association”

2. Set association by operating the wall controller and devices to be controlled:

To control a Z-Wave device from the Wall Controller the node ID of this device needs to be assigned to one of 
the four association groups. This is a three-step process: 

1. Press and hold down “ALL ON/OFF” button on the wall controller for over 3 seconds, LED indicator turns on.
2. Click any Group number button on the wall controller within 25 seconds to add the device to be controlled to 
the association group, double click any Group number button on the wall controller within 25 seconds to 
remove the device to be controlled to the association group.
3. Operate the device to be controlled to send Node Information Frame (please refer to the device manual) 
within 15 seconds, or set the device to exclusion mode within 15 seconds, since it will send Node Information 
Frame in exclusion mode, LED indications are as follows:

LED blinks 5 times to indicate that the wall controller failed to add the associated device (the association group 
has already added maximum quantity associated devices that it supports ).

LED blinks 10 times to indicate that the wall controller added the associated device successfully.

LED blinks 8 times to indicate that the wall controller removed the associated device successfully.

Group

Identifier

Group Name

Max Nodes

Description 

1. Send “Command Class Device Reset Locally” to 
associated devices of this group to report factory 
reset information when factory reset the wall 
controller.
2. Double click a group number of the wall controller 
to send command to associated devices of this 
group using “Command Class Central Scene”.

1. Press and hold down button "1" to activate group 
in order to switch the associated devices with a 
Basic Set or dim these devices by using the two 
brightness buttons or adjust color temperature by 
using color wheel.
2. Short press Scene button S1/S2/S3/S4, direct 
control of associated devices using Scene 
Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
3. Press and hold down Scene button S1/S2/S3/S4, 
direct control of associated devices using Scene 
Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

2

Lifeline

Launch 1

1

12

1. Press and hold down button "3" to activate group 
in order to switch the associated devices with a 
Basic Set or dim these devices by using the two 
brightness buttons or adjust color temperature by 
using color wheel.
2. Short press Scene button S1/S2/S3/S4, direct 
control of associated devices using Scene 
Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
3. Press and hold down Scene button S1/S2/S3/S4, 
direct control of associated devices using Scene 
Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

4

Launch 3

12

1. Press and hold down button "2" to activate group 
in order to switch the associated devices with a 
Basic Set or dim these devices by using the two 
brightness buttons or adjust color temperature by 
using color wheel.
2. Short press Scene button S1/S2/S3/S4, direct 
control of associated devices using Scene 
Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
3. Press and hold down Scene button S1/S2/S3/S4, 
direct control of associated devices using Scene 
Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

3

Launch 2

12

1. Press and hold down button "4" to activate group 
in order to switch the associated devices with a 
Basic Set or dim these devices by using the two 
brightness buttons or adjust color temperature by 
using color wheel.
2. Short press Scene button S1/S2/S3/S4, direct 
control of associated devices using Scene 
Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
3. Press and hold down Scene button S1/S2/S3/S4, 
direct control of associated devices using Scene 
Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

5

Launch 4

12

Reviews: