- 2 -
No.
Name
Qty.
Photos
1
Installation & Operation Manual
2
Wire-controller
3
Heat exchanger connector
4
Wire-controller signal wire
5
Heat Pump Unit
Page 1: ...Operation Manual Swimming Pool Heat Pump Commercial Type Model Number YC 050TA1 Thank you very much for purchasing our product please keep and read this manual carefully before you install heat pump...
Page 2: ...2 No Name Qty Photos 1 Installation Operation Manual 1 2 Wire controller 1 3 Heat exchanger connector 2 4 Wire controller signal wire 1 5 Heat Pump Unit 1...
Page 3: ...s not suitable for using in the Winter 7 C when the unit leave unused in Winter the water reserved in the pipe network system must be drained Content 1 Accessories Description 4 2 Attention for safety...
Page 4: ...y has no responsibility for all the problem cause by the auxiliary electric heater 2 Attention for safety Range of application 1 Power supply 380V 3N 50Hz 2 Environment temperature 7 C 43 C 3 Working...
Page 5: ...peration failure electric shock fire hurt leaking etc Must not be unauthorized reformed otherwise it may cause electric shock or fire When needs to be repaired please entrust after sale service depart...
Page 6: ...t Third the refrigerant liquid releases the pressure by passing the expansion valve then becomes the low temperature and low pressure liquid Fourth the refrigerant liquid flows into the evaporator and...
Page 7: ...special harsh environmental conditions 4 2 Installation check Check the model number name etc avoid incorrect installation Make sure enough space for installation and maintenance Make sure barrier fre...
Page 8: ...eep the following indicated space for operation and maintenance first before installation Figure 3 Installation space 1200 1200 Figure2 The distance to top barrier 2000 500 600 500 1200 500 500 600 12...
Page 9: ...bolt Screw nut washer Shock absorb Heat Pump Drainage tray Figure 5 Reserved installation base 4 6 Hoisting attention Please use four or more soft lifting belts to move the sets Figure 6 Please use pr...
Page 10: ...yer Stable water velocity shall be ensured so that excessive throttling can be avoid When moving water inlet and outlet pipe shall not be used for hanging only the holes on the beam of the base can be...
Page 11: ...ram Figure 8 Diagram I Single unit for reference Figure 9 Diagram II Multiple units for reference The one way valve is suggested for each unit to prevent the water back flow The system can be combined...
Page 12: ...water level and main unit total pipelines resistance determined by the hydraulic calculation pressure loss of main unit see the nameplate on heat pump NOTE When multi paralleled the water pump head i...
Page 13: ...ng reliable connection and the external grounding is effective Wiring must be constructed by the professional installation technicians in accordance with the circuit diagram Power line and signal line...
Page 14: ...igure 13 Power cable terminal 7 2 Electrical Wiring Specification Model No Electrical Wiring Specification YC 050TA1 3 6mm 2 4mm 7 3 Circulation pump installation The heat pump only provide the signal...
Page 15: ...15 Figure 15 7 4 Wire controller connection Figure 16...
Page 16: ...16 7 5 Electric wiring diagram Figure 17...
Page 17: ...nt temperature and exhaust temperature etc Power cut memory function When power cut the clock will still work Timing on off Automatic defrosting Forced to defrost Large LCD display Has perfect protect...
Page 18: ...F OFF OFF Master unit ON OFF OFF OFF Slave unit 1 OFF ON OFF OFF Slave unit 2 ON ON OFF OFF Slave unit 3 OFF OFF ON OFF Slave unit 4 ON OFF ON OFF Slave unit 5 OFF ON ON OFF Slave unit 6 ON ON ON OFF...
Page 19: ...efrosting delay Flashing Refrigerant recovery Constantly bright Anti freezing Constantly bright Fast heating Flashing Fast heating delay Constantly bright Maintenance mode Constantly bright Compressor...
Page 20: ...t the water temperature 2 Press the button for 3 seconds enter into maintenance status 3 In maintenance status page down 4 Set the parameter value 4 Time button 1 In the main interface press the butto...
Page 21: ...rature and shows on the display press or button to turn up or turn down water temperature press or button for more than 1 second can adjust the temperature faster Press button or without any operation...
Page 22: ...the timing ON OFF setting Water feed timing setting In the main interface press and button for 3 seconds enable or disable water feed timing function when enable the function will enter into the setti...
Page 23: ...us query interface press or button to query each status Press button or without any operation for 30 seconds will exit status query interface No Name Note No Name Note 01 Water inlet water tank temp M...
Page 24: ...ion pump 0 OFF 1 ON 35 Cooling coil temp 3 Measured value 85 1 high speed motor 0 OFF 1 ON 36 Enthalpy enhanced valve 4 inlet temp Measured value 86 1 low speed motor 0 OFF 1 ON 37 Enthalpy enhanced v...
Page 25: ...r is in the normal display state the button is locked when there is no button operation for more than 60 seconds press the any button to unlock 8 2 3 Error code Error Code Description E01 Phase fault...
Page 26: ...mp sensor 3 fault E61 Exhaust temp sensor 4 fault E62 Cooling coil temp sensor 3 fault E63 Cooling coil temp sensor 4 fault E64 High exhaust temp protection 3 E65 High exhaust temp protection 4 E66 Co...
Page 27: ...ptable Check if there is vibration or abnormal sound when the system is functioning Check if the wind noise and condensate water produced by the system affect the environment around Check if there is...
Page 28: ...periment never let the refrigeration system filling oxygen ethane or other flammable harmful gas we can only adopt compressed air fluoride or refrigerant for such experiment 10 4 To remove the compres...
Page 29: ...29 11 Fault analysis and elimination method...
Page 30: ...alve Electronic Expansion Valve Air Flow Direction Vertical Type Water Flow Volume m3 h 20 000 Net Dimensions L W H mm 1410 748 1000 Working temperature range C 7 43 Noise dB 65 Net Weight kg 250 Wate...
Page 31: ...After sale service If your hot water heater can not operate normally please turn off the unit and cut off the power supply at once then contact with our service center or technical department...
Page 32: ......