Table 1: Electrical Characteristics

1

 

Typical Electrical Data 

at STC: 25



C, 1000 W/m

2

 and AM 1.5

 

Model 

SPR-E-Flex-110 

SPR-E-Flex-100 

Nominal Power

 

(Pnom) 

110 W 

100 W 

Power Tolerance 

+/

3% 

+/

3% 

Rated Voltage (Vmpp) 

18.5 V 

17.5 V 

Rated Current (Impp) 

6.0 A 

5.8 A 

Open circuit voltage (Voc) 

21.7 V 

21 V 

Short curcuit current (Isc) 

6.3 A 

6.2 A 

Power Temp Coeffiecient 

0.35%/

° 

Voltage Temp Coefficient 

58.9 mV/

° 

Current Temp Coefficient 

2.6 mA/

° 

Max. System Voltage 

45 V 

Series Fuse Rating 

15 A 

 

 

 

Rated electrical characteristics are within 10% of measured values at Standard Test Conditions of: 1000W/m^2, 25°C cell temperature and solar spectral irradiation of AM 1.5 spectrum.

 

4.0

   

Electrical Connections  

The connectors used in these panels allows for modules to be connected in series or parallel. However, connecting the panels in this manner can put the by-pass diode in 
the panel and the battery at risk for damage and could create a safety issue.  Please read the DANGER! note below.   

Series Connection 

Connecting the panels in series increases the voltage of the system, so the two panels produce double the voltage as compared to one panel.  This high voltage 
can cause damage to the battery and could cause a safety issues.  Please read the DANGER! note below. 
To connect panels in series, connect the negative (-) plug of panel #1 to the positive (+) plug of the panel #2.  See Figure1 left. 

Parallel Connection  

Connecting the panels in parallel increases the current of the system, so the two panels produce double the current as compared to one panel.  This high current 
may cause damage to the battery and the by-pass diode in the junction box and cause a safety issue.  Please read the DANGER! note below. 
To connect panels in parallel, connect the positive (+) plug of panel #1 to the positive (+) plug panel #2 Connect the negative (-) plug of panel #1 to the negative (-) 
plug of panel #2. See Figure 1 Right.  In this configuration, cable adapters will be needed.

 

 

                                       

 

 

Figure 1: Schematic of two panels in series and parallel. 

 

 

                                                 

1

 

For models not shown here, please contact SunPower technical support or visit 

www.sunpower.com

. Electrical parameters are measured at Standard Test Conditions (STC). 

The series fuse must have an interrupting rating that is equal to or greater than the maximum fault current that the fuse is required to interrupt, including contributions from all 
connected sources of energy. 

 

DANGER!

   

Connecting  panels  in  series  will  double  the  voltage  output  of  the  panels,  reaching  voltages  as  high  as  >  40V.    If  attached  to  a  low  voltage 
battery,  e.g.  a  12V  battery,  this  high  voltage  could  cause  damage  to  the  battery  and  could  cause  a  safety  issue.    Please  check  the  charging 
characteristics of the battery in use. 
 
Connecting panels in parallel will double the current output of the panels, reaching currents as high as > 12amps.  If attached to a battery for 
charging, this high current may cause damage to the battery and cause a safety issue.  Please check the charging characteristics of the battery 
in use.  Additionally, if one of the panels were to go into reverse bias, for example by shading, damage to the by-pass diode in the junction box 
may occur.  Avoid shading either panels.  SunPower does not recommend connecting these panels in parallel if shading will occur. 