background image

Installation

6

7

Control Panel

1.  Set temperature indicator

2.  Room temperature indicator

3.  Low fan speed indicator

4.  High fan speed indicator

5.  Automatic mode indicator

6.  Cooling mode indicator

7.  Fan mode indicator

8.  Heating mode indicator

(for models with heating options)

Mounting the exhaust pipe

•  The supplied exhaust hose can be

extended from 1 foot to 5 feet
for mounting. It is recommended that
you use the shortest possible length of hose.

•  Take care to prevent any kink or

bend in the middle of the exhaust
hose, as this will trap hot exhaust air,
which will radiate back into the room.

Installation of the Carbon Filter

Setting Mode/Function

Press the MODE button to select the required working mode: Automatic, Cooling, Fan or Heating (Heating is only
available for WA-1210H). The green indicator illustrating your selected mode lights up.  It is recommended to select
Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please see
below) that cannot be changed.

The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed.

Auto Mode

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:
• Cool when room temperature is higher than 75ºF
• Heat when room temperature is lower than 68ºF (WA-1210H only)

If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode.  Again, when in Auto Mode, the temperature
settings cannot be changed.

Setting the Temperature in Cooling or Heating Mode

T

he display window’s default is to display the ambient room temperature.  The green indicator light under RT is on.

(RT = Room Temperature)

To set your desired temperature, press the Temperature up or down buttons (ranging from 64ºF to 90ºF).  Each press
will increase or decrease your set temperature by 1ºF.  When pressing the temperature up or down buttons, the
window will change to display your set temperature. At this time, the green indicator will light under ST (Set
Temperature).  Once the temperature up or down buttons is released, the window will return to displaying the
ambient temperature after a second.

Note:

  When unit is in the following modes:   Auto, Cool, or Heat - the compressor will cool/heat the room to reach

the set temperature.  Once the ambient temperature has reached the set temperature, the compressor will stop and
unit will run in Fan mode.  To conserve energy, the compressor will not start immediately after a couple degrees
increase or decrease, but will wait for a 5ºF allowance.  For example:

In Cooling Mode with a set temperature of 70ºF

When compressor first stops after reaching 70ºF, unit will auto-switch to Fan.
Compressor will start cooling again when ambient temperature increases to 75ºF or above.

In Heating Mode with a set temperature of 72F

When compressor first stops after reaching 72ºF, unit will auto-switch to Fan.
Compressor will start heating again when ambient temperature drops to 67ºF or below.

In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)

Compressor will start cooling again when ambient temperature reaches above 80F or will start heating when ambient
temperature drops below 63ºF.

9.

Timer operation indicator

10. Compressor Indicator

11.  Temperature up selector

12.  Temperature down selector

13.  Fan speed selector

14. Mode (function)

option selector

15. Timer selector

16.  ON/OFF (power) selector

17. Display window

1.  Remove the filter frame from the unit by

pressing down on tabs and pulling forward.

2. Separate the filter from the filter frame.

3. Remove the active carbon filter 

from its plastic bag.

4. Insert the active carbon filter 

into the filter frame.

5.  Fix the filter by reassembling 

the fixer onto the filter frame.

6.  Re-fit the filter frame

inside the unit.

7.  It is recommended to

replace the carbon filter
every 3 to 6 months.

WARNING!

The length of the exhaust pipe is specially
designed according to the specification of
this product.

Do not replace or extend it with your own hose
as this could cause the unit to malfunction.

Operation - Electronic Control Models

Summary of Contents for WA-1210E

Page 1: ...er repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of SUNPENTOWN The warranty applies to the use of this product in the United States Warranty does not include freight charges This GUARANTEE is in addition to your Statutory Rights Dear Customer Please kee...

Page 2: ...clean Set the unit to maximum cooling and high speed fan initially then adjust the unit to a comfortable setting NOTE It is recommended to turn on the air conditioner when the room temperature is around 75 F Do not wait until the room is excessively hot 1 Maintenance 12 Always unplug the unit from the mains before beginning the cleaning Cleaning the Housing Use a soft damp cloth to wipe the body c...

Page 3: ...the warm air Do not cover or obstruct the appliance inlet or outlet grilles Figure 2 To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas The unit will cool when the room temperature is between 64 F and 110 F depending on the thermostat setting Do not sit or place objects on the unit Do not touch the unit with wet damp hands or w...

Page 4: ...er button is not pressed the unit will work continuously By pressing the timer button but without turning on the unit you can PRE SET the time for the machine to work For example if you press the timer to 2 the unit will come on automatically after 2 hours All the above functions can also be performed with the supplied remote control This remote control requires 2 AAA batteries to operate Regulati...

Page 5: ...ur set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temperature after a second Note When unit is in the following modes Auto Cool or Heat the compressor will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperat...

Page 6: ...between hose and wall 15 Cap for Round Connector 16 Remote Control Electronic control models only Operation Mechanical Control Models 9 1 Power indicator 2 Fan operating indicator 3 Cooling operating indicator 4 Full water indicator 5 Thermostat 6 Speed switch with options for LOW FAN HIGH FAN LOW COOL HIGH COOL 7 Timer 1 8 hours as well as ON OFF switch Turning ON OFF Set TIMER to ON for continuo...

Page 7: ...he Draining into a Container Use a Shallow Container or Dish 1 Turn off the unit 2 Position a flat container or dish under the drain hole Do not allow the water to drip continuously into the container as it might easily overflow 3 Remove the drain knob rubber plug from the drain hole The condensed water will drain out automatically 4 When the container is almost full replace the rubber plug into t...

Page 8: ...cording to its own settings The unit seems to do little Is there direct sunshine Please close the curtains or blinds Are too many windows or doors open Are there too many people in the room Is there something in the room producing lots of heat The unit seems to do nothing Is the dust filter dirty Is the air intake or outlet blocked up Is the room temperature within the selected temperature 5 F The...