background image

 

 Last Update 4/2/2008 

SUNPAK S34 Heater Manual 

© Techrite Controls Australia 

1213mm 

203mm 

203mm 

240V 

12mm 

Part No. 

Model 

Description 

Dimension (mm) 

Type 

12002-2 

S34-NAT 

SUNPAK 34mJ/Hr Heater  203 x 203 x 1213 

Natural Gas 

12004-2 

S34-LP 

SUNPAK 34mJ/Hr Heater  203 x 203 x 1213 

Propane Gas 

9.5mm 

H = Height 
S = Spread of heat 
 

MODEL S34 

Horizontal 

 

2.74m 

3.66m 

30

°

 Angle 

 

2.44m 

3.66m 

SUNPAK w ill raise the comfort level 3 to 6

°

C outdoors. The 

above coverage table w as based on still breeze 

conditions. U nder w indy conditions, more heat w ill be 

required. For example, an 8km/h breeze typically  w ill 

require tw ice as many  heaters to achieve the same 

comfort level. It is recommended that a w indsw ept patio 

be designed w ith w ind breaks in order to stabilize the patio 

environment. 

ANGLE MOUNTING 

 

The  SU NPAK heater may  be angle mounted to a 

max imum of 30

°

 to accommodate mounting the 

heaters around the patio.  

MODEL S34 

( see chart on page 5) 

Summary of Contents for S34

Page 1: ...4444 Fax 61 3 9546 6069 Authorised Distributor Applied Climat e Cont rol Aust raliaW ide Phone 1300 798 088 Techrite Controls Australia Pty Ltd ABN 30 006 959 495 Email info t echrit e com au Website www t echrit e com au www techrite com au The SUNPAK by TECHRITE Controls Australia A wholly Australian owned company Your patio will shine with a Your patio will shine with a SUNPAK stainless steel h...

Page 2: ...and Features 3 Sequence of Operation Maintenance Trouble Shooting and warranty 4 Minimum clearance to combustible materials Diagrams 5 Minimum clearance to combustible materials and angle mounting 6 Installation and Mounting 7 Unit Clearance Enclosure definitions 8 Suggested heater locations and configurations 9 Proper mounting location 10 Lighting Servicing Instructions and Installation Trouble S...

Page 3: ...ives SUNPAK the versatility to fit easily into a wide variety of patio situations WARNING Appliance must be installed to the requirements of Gas Code AS5601 and the local authorities both Gas and Electrical Retain these instructions for future reference Installation of SUNPAK heaters should only be performed by an authorised person HEATER FEATURES HEATER FEATURES Automatic operation Slim profile D...

Page 4: ...the front grille SUNPAK heaters must be installed in such a manner as to allow the products of combustion or hot gases to vent out the top portion of the heater When operating normally only radiant heat passes through the front grille If conditions exist which force hot gases through the front grille of the heater the installation must be altered to correct the condition Limited Warranty and Servi...

Page 5: ...ralia 1213mm 600mm 203mm 1206mm 1248mm 1200mm Minimum clearance to combustible materials 430mm 430mm 1200mm Minimum clearance to combustible materials 430mm 430mm 430mm 430mm 1200mm Minimum clearance to combustible materials S34 WIRING DIAGRAM 50mm 600mm 600mm 600mm 600mm ...

Page 6: ... 44m S 3 66m SUNPAK w ill raise the comfort level 3 to 6 C outdoors The above coverage table w as based on still breeze conditions Under w indy conditions more heat w ill be required For example an 8km h breeze typically w ill require tw ice as many heaters to achieve the same comfort level It is recommended that a w indsw ept patio be designedw ithw ind breaks in order to stabilize the patio envi...

Page 7: ... placed on or near the appliance Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance Installation of appliances fitted to fixed gas supply systems and repair of all appliances must be carried out by a qualified service person It is imperative that control compartment burners and circulating air passageways of the appliance be k...

Page 8: ... natural convection Any enclosure in which the appliance is used shall comply with one of the following In the case of balconies at least 20 of the total wall area must remain open and unrestricted An enclosure w ith walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls Withi...

Page 9: ...Last Update 4 2 2008 9 SUNPAK S34 Heater Manual Techrite Controls Australia ...

Page 10: ...ite Controls Australia SUNPAK S34 HEATER Proper Mounting Location Heater is improperly mounted at greater than a 30 angle resulting in combustion gases spilling out of the front resulting in deterioration of the front grille and damaging heater components ...

Page 11: ...e inst allingt he burner D To remove t he pilot elect rode assembly disconnect t he elect rical w ire Det ach t he pilot t ubing Removet hetw o 2 screws holding t he pilot elect rode in place E Remove 9 5mm hex locknut locat ed inside burner orifice bracket holding piping assembly t o burner A 22mm 12 point w rench w ill be handy t o loosen t he 9 5mm locknut from the t op of t he heat er F Remove...

Page 12: ...AL DOMESTIC CONTROLS ATMOSPHERIC BURNERS THERMOSTATS TEMPERATURE CONTROL INSTRUMENTS MISCELLANEOUS Visit us at www techrite com au TECHRITE CONTROLS AUSTRALIA Head Office 12 Yiannis Court Springvale VIC 3171 Website www techrite com au Email info techrite com au MELBOURNE Ph 61 3 9549 4444 Fax 61 3 9546 6069 APPLIED CLIMATE CONTROL Authorised Dealer Australia wide Ph 1300 798 088 TECHRITE CONTROLS...

Reviews: