Warning: within 10 minutes after the controllers stops charging, if the
battery's poles are reversely connected, internal components of the controller may get
damaged.
Note:
1) The battery's fuse or breaker shall be installed as close to the battery sideas
possible, and it's recommended that installation distance be not more than
150mm.
2) If no remote temperature sensor is connected to the controller, the battery
temperature value will stay at 25 °C.
3) If an inverter is deployed in the system, directly connect the inverter tothe
battery, and do not connect it to the controller's load terminals.
3. Product Operation and Display
3.1 LED Indicators
○
1
---PV array indicator
Indicating the controller's current charging
mode.
○
2
---BAT indicator
Indicating the battery's current state.
○
3
---LOAD indicator
Indicating the loads' On/ Off and state.
○
4
---ERROR indicator
Indicating whether the controller is
functioning normally.
PV array indicator:
Steady on, charging in max. power
Slow flashing, boost charging
Single flashing, floating charging
Quick flashing, equalizing charging
Double flashing, current-limited charging
No.
Indicator state
Charging