13 

 

GROUNDING INSTRUCTIONS 

 

WARNING:

 This treadmill requires a power source of 

10 amps (100-120V)

 in order to properly 

operate. For your safety, as well as the safety of others, please verify that the power source is correct 
before  powering  the  treadmill.  Any  power  supply  source  above  or  below  this  level  could  cause 
significant damage to the treadmill and/or user. 

 
GROUNDING METHODS: 

This treadmill must be grounded. Should the treadmill malfunction or breakdown, grounding provides a 
path  of the  least resistance for  electrical current  to  reduce the risk  of  electric shock.  This product  is 
equipped with a plug that has an equipment-grounding conductor and a grounding plug. The plug must 
be  plugged  into an appropriate  outlet  that is  properly installed and grounded in  accordance with all 
local codes and ordinances.   

 
 
 
 
 
 
 
 
 
 

CAUTION: 

 

Improper  connection  of  the  treadmill  can  result  in  risk  of  electric  shock.  Check  with  a  qualified 
electrician or serviceman if you are unsure whether the treadmill has been properly grounded. Do not 
modify the plug provided with the treadmill. If it will not fit the outlet, have a proper outlet installed by a 
qualified  electrician.  Ensure  that  the  treadmill  is  connected  to  an  outlet  which  contains  the  same 
configuration as the plug. Do not use an adaptor for this treadmill. 

 

WARNING! 

1. 

NEVER

 use a ground fault circuit interrupt (GFCI) outlet with this treadmill. Route the power cord 

away  from  all  moving parts of  the  treadmill,  including  the  air  pressure  cylinder and transportation 
wheels. 

2. 

NEVER

 operate the treadmill using a generator or UPS power supply. 

3. 

NEVER

 remove any cover on this treadmill without first disconnecting the power cord.   

4. 

NEVER

 expose the treadmill to rain or moisture. This treadmill is not designed for outdoor use or 

use in any high humidity environment. 

 

 

 
 

 

 

GROUNDING METHOD 

Summary of Contents for SF-T7917

Page 1: ...UAL IMPORTANT Please retain owner s manual for maintenance and adjustment instructions Your satisfaction is very important to us PLEASE DO NOT RETURN UNTIL YOU HAVE CONTACTED US support sunnyhealthfit...

Page 2: ...ter Return this treadmill to a service center for examination and repair 4 Keep the cord away from heated surfaces 5 Never operate the treadmill with the air openings blocked Keep the air openings fre...

Page 3: ...lid flat level surface with a protective cover for your floor or carpet To ensure safety the equipment should have at least 8 feet 240CM of free space behind it and 2 feet 60CM on each side Do not pla...

Page 4: ...unction only if the safety key is inserted into the computer console In case of emergency remove the safety key to immediately stop the running belt and shut off the treadmill The display screen will...

Page 5: ...4 EXPLODED DIAGRAM...

Page 6: ...150 87 9 35 2 61 Zip Tie ST 100mm 6 20 Screen Upper Cover 830 6 599 3 169 9 1 62 Zip Tie ST 200mm 8 21 Screen Bottom Cover 404 8 134 60 6 1 63 Left Post Cover 1 22 Screen Panel 293 6 273 9 37 8 1 64 R...

Page 7: ...0 4 94 Bolt M8 100 1 109 Optical Sensor 1 95 Screw M4 8 3 110 Allen Wrench 100 50 S5 1 96 Overload Protector 10A 1 111 Screw ST3 0 8 10 97 Filter 15A 1 112 Spanner 13 16 1 98 Plastic Washer 4 8 200mm...

Page 8: ...and secure with Allen Wrench No 110 Attach the Computer Bracket No 6 to the Left Right Upright Tubes No 4 No 5 with 2 Internal Tooth Lock Washers No 88 and 2 Bolts No 71 Tighten and secure with Allen...

Page 9: ...ng belt STEP 3 Attach the Left Right Post Covers No 63 No 64 to the Left Right Upright Tubes No 4 No 5 with 4 Screws No 77 Tighten and secure with Spanner No 112 77 ST4 2 10 4PCS 112 13 16 1PC STEP 4...

Page 10: ...nd and set it at 2 1 MPH to check if the Running Belt No 9 drifts from the center Adjust the Running Belt No 9 according to instructions below with Allen Wrench No 110 If the Running Belt No 9 moves t...

Page 11: ...the Running Board No 10 Repeat this process for the other side 2 The moving parts should turn freely and quietly Abnormal moving parts will affect the safety of the treadmill Inspect and tighten bolts...

Page 12: ...1 successfully locks into the tube you will hear a clicking sound Before lowering the Main Frame No 1 ensure that the space directly underneath is clear of any objects Grasp the Main Frame No 1 at pos...

Page 13: ...nd of the treadmill Next place one foot at position B to hold the bottom end of the treadmill steady With your foot at position B slowly tilt the top of the treadmill downward towards the ground Once...

Page 14: ...es CAUTION Improper connection of the treadmill can result in risk of electric shock Check with a qualified electrician or serviceman if you are unsure whether the treadmill has been properly grounded...

Page 15: ...re out of reach of children DISPLAYS Power On Press START button normal startup after 5 seconds countdown Program Function 15 preset programs 3 customized programs 4 kinds of motion modes Time countdo...

Page 16: ...lect the program from manual mode P01 P15 U1 U3 and FAT Manual program is default operating program of the system The default speed is 0 6 MPH the maximum speed is 10 MPH MODE In standby mode press th...

Page 17: ...7 4 3 5 0 5 0 3 1 2 5 1 8 1 8 3 7 3 1 2 5 1 2 Incline 3 3 3 4 4 5 5 5 4 4 4 4 5 5 3 3 3 2 2 2 P06 Speed 1 2 2 5 2 5 2 5 3 1 3 7 5 0 5 0 3 7 4 3 5 0 5 0 3 7 2 5 2 5 1 2 3 1 2 5 1 8 1 2 Incline 3 5 5 5...

Page 18: ...eration time press START BODY MASS INDEX Press the PRG button until the window displays FAT to access Body Mass Index Press MODE to enter F 1 F 2 F 3 F 4 F 5 F 1 SEX F 2 AGE F 3 HEIGHT F 4 WEIGHT F 5...

Page 19: ...it can set circulation For example the setting range of time is 5 00 99 00 when setting to 99 00 then press SPEED return to 5 00 It will keep circulation You can use SPEED to go up down The countdown...

Page 20: ...lt the dealer or an experienced radio TV technician for help FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This...

Page 21: ...hange the control board Check if voltage is AC 100 120V E3 Speed inductor failed Check if the wire of optical sensor were inserted properly Change the control board E4 Incline learning failed Check if...

Page 22: ......

Reviews: