WARRANTY – SL6AV 

 
This range of product is covered by a limited 3 year warranty against component failure or 
faulty workmanship from the date of installation.  
 
A faulty unit should be returned in the first instance to the dealer  from which the unit was 
purchased. 
 
Damage to the unit due to misuse, power surges, lightning strikes or installation that is not 
in accordance with the manufacturer’s instruction may void the warranty.  
 
Valves  and  actuators  are  covered  by  a  twelve  month  warranty  at  the  discretion  of  their 
manufacturer. 
 
Warranty does not cover travel costs to or from installation site. 
 
If the power cord is damaged, do not use the controller; return the unit to the supplier for 
repair. 
 

Customer Record

. (To be retained by the customer) 

 
 
Dealer/Installer Name 

……………………………………………… 

 
Serial Number 

 

……………………………………………… 

 
Date Installed 

 

……………………………………………… 

 
For service assistance phone 1300 130 693 
 
VIC 

03 9887 2131 

NSW  

02 9838 0000 

QLD  

07 5597 7360 

 

Factory 6

 

62 Parkhurst Drive 

 

7-9 Activity Crescent

 

 

Knoxfield  VIC  3180 

 

Molendinar 4214

   

 

Victoria Australia   

 

Queensland Australia

 

 

Unit 2 
20-22 Foundry Road, 
Seven Hills 2147 
New South Wales Australia

 

 

 
www.sunloversolar.com.au

 

 

MODEL SL6 AV Deluxe Digital Solar Controller 

 

OPERATING INSTRUCTIONS 
AUTO

 is normal operating mode used during the Pool Swimming Season. You may set 

the desired pool limit by pressing the UP or Down Buttons. The display shows the pool 
temperature  then  flashes  the  limit  setting  and  light;  the  HEAT  light  will  be  on  when 
solar gain is available. 
 

Manual 

is used to test the system. To select manual mode press the SELECT button 

until  the  HEAT  light  is  illuminated.  The  valve  will  then  open,  or  close  if  it  has  been 
running. To return to normal run simply press the SELECT button till the AUTO light is 
illuminated. The SL6 AV will automatically return to AUTO run after 30 minutes, with a 
limit of 30 degrees.

 

 
Roof 

displays  the  roof  sensor  temperature,  a  hot  roof  indicates  that  solar  gain 

(heating)  is  available,  if  left  unattended  in  this  mode  the  SL6  AV  will  automatically 
return to AUTO run after 3 minutes. 

 
Winter 

should be selected when the pool is not being used for extended periods. The 

valve  will  be  turned  for  3  minutes  every  day  at  the  same  time  Winter  Mode  was 
selected.  This  will  assist  in  the  systems  off-season  maintenance.  To  enter  this  mode 
press  the  SELECT  button  till  the  WINTER  light  is  illuminated,  the  display  will  then  go 
blank and the valve will turn to roof for three minutes. Ensure winter mode is activated 
during the filter run times only. If the power is interrupted during winter mode the SL6 
AV will continue to count time accurately. 
 

Tropical 

is used to assist in cooling over heated pools. If the limit has been reached, 

which is indicated by the limit light on, and the roof temperature drops below the limit 
temperature (usually some time late at night) the valve will turn and divert pool water 
to  the  roof  to  cool  it  down.  The  filter  pump  must  be  set  to  filter  at  night  for  this 
operation.  To  set  this  function  press  the  SELECT  button  till  the  TROP  light  is 
illuminated.  To  switch  back  to  Summer  Mode  press  the  SELECT  button  till  the  AUTO 
light is illuminated. 
 

OPERATION 

The SL6 AV will turn the motorised valve when the roof temperature is higher than the 
pool (pipe) temperature by 8°C and off at 4°C. The HEAT light will flash for 30 seconds 
when constant flow from the main filter pump is first detected (if fitted), then turn the 
divert  valve.  When  the  pool  temperature  reaches  the  limit  setting  the  limit  light  will 
flash, it will remain in this state while the pool is at limit then divert back to the roof if 
the pool temperature drops and the roof is still hot. 