WARRANTY – SL6AV
This range of product is covered by a limited 3 year warranty against component failure or
faulty workmanship from the date of installation.
A faulty unit should be returned in the first instance to the dealer from which the unit was
purchased.
Damage to the unit due to misuse, power surges, lightning strikes or installation that is not
in accordance with the manufacturer’s instruction may void the warranty.
Valves and actuators are covered by a twelve month warranty at the discretion of their
manufacturer.
Warranty does not cover travel costs to or from installation site.
If the power cord is damaged, do not use the controller; return the unit to the supplier for
repair.
Customer Record
. (To be retained by the customer)
Dealer/Installer Name
………………………………………………
Serial Number
………………………………………………
Date Installed
………………………………………………
For service assistance phone 1300 130 693
VIC
03 9887 2131
NSW
02 9838 0000
QLD
07 5597 7360
Factory 6
62 Parkhurst Drive
7-9 Activity Crescent
Knoxfield VIC 3180
Molendinar 4214
Victoria Australia
Queensland Australia
Unit 2
20-22 Foundry Road,
Seven Hills 2147
New South Wales Australia
www.sunloversolar.com.au
MODEL SL6 AV Deluxe Digital Solar Controller
OPERATING INSTRUCTIONS
AUTO
is normal operating mode used during the Pool Swimming Season. You may set
the desired pool limit by pressing the UP or Down Buttons. The display shows the pool
temperature then flashes the limit setting and light; the HEAT light will be on when
solar gain is available.
Manual
is used to test the system. To select manual mode press the SELECT button
until the HEAT light is illuminated. The valve will then open, or close if it has been
running. To return to normal run simply press the SELECT button till the AUTO light is
illuminated. The SL6 AV will automatically return to AUTO run after 30 minutes, with a
limit of 30 degrees.
Roof
displays the roof sensor temperature, a hot roof indicates that solar gain
(heating) is available, if left unattended in this mode the SL6 AV will automatically
return to AUTO run after 3 minutes.
Winter
should be selected when the pool is not being used for extended periods. The
valve will be turned for 3 minutes every day at the same time Winter Mode was
selected. This will assist in the systems off-season maintenance. To enter this mode
press the SELECT button till the WINTER light is illuminated, the display will then go
blank and the valve will turn to roof for three minutes. Ensure winter mode is activated
during the filter run times only. If the power is interrupted during winter mode the SL6
AV will continue to count time accurately.
Tropical
is used to assist in cooling over heated pools. If the limit has been reached,
which is indicated by the limit light on, and the roof temperature drops below the limit
temperature (usually some time late at night) the valve will turn and divert pool water
to the roof to cool it down. The filter pump must be set to filter at night for this
operation. To set this function press the SELECT button till the TROP light is
illuminated. To switch back to Summer Mode press the SELECT button till the AUTO
light is illuminated.
OPERATION
The SL6 AV will turn the motorised valve when the roof temperature is higher than the
pool (pipe) temperature by 8°C and off at 4°C. The HEAT light will flash for 30 seconds
when constant flow from the main filter pump is first detected (if fitted), then turn the
divert valve. When the pool temperature reaches the limit setting the limit light will
flash, it will remain in this state while the pool is at limit then divert back to the roof if
the pool temperature drops and the roof is still hot.