Make sure voltage setting on the machine is set
to closest voltage at the wall
206
Top heater has low output during session -
current below 0.5 amp
Top heater current is low, which will reduce heater
performance.
•
Check heater fuse on AC board
•
If fuse is good check AC power at heater
•
If no power replace AC board or cable
•
If power is good at the heater, replace heater
207
Bottom heater has low output during
session - current below 0.5 amp
Bottom heater current is low, which will reduce heater
performance.
•
Check heater fuse on AC board
•
If fuse is good check AC power at heater
•
If no power replace AC board or cable
•
If power is good at the heater, replace heater
208
Cannot rinse - the door is open
Close the door for the rinse cycle to begin.
•
Check Diagnostic Inputs under the Technical
tab.
•
If door does not read closed when the door is
closed, check door magnets
•
If door magnets are present, check magnet
positioning and door switches on roof
209
Drain pump fault - pump not emptying the
sump
Drain not emptying sump basin. Rinse will not start
while to basin is full see section T4.for help.
210
Cannot rinse - emergency float is high
The sump basin is too full. Rinse cycle will not start.
See section T4 for more help.
211
Rinse was stopped due to door opened
Door was opened during the rinse cycle, so rinse cycle
was halted.
212
Audio Error - SD card message problem
Booth not reading SD card properly. Session will run
without audio. See section T7 for help.
213
Top heater malfunction during idle
Occurs when current exceeds 0.2 amps while idle. Top
heater cut off.
214
Bottom heater malfunction during idle
Occurs when current exceeds 0.2 amps while idle.
Bottom heater cut off.
Orange Faults
Fault
Code
Display Message
Description
403
Liquid remaining in reservoir AFTER
purge- (current reservoir level)
Displays the current volume in reservoir after a purge
based on a scale of 1 -19. Ignores values of 2 or below.
•
Run a purge and watch the nozzle
•
If it sprays solution, check and clean flow
system (puncture pin, restrictor block)
•
If it does not spray solution, replace reservoir
float