▶ Set the address
If you want to control the devices at once through RS-485(using communication function), then the proper
addresses should be addressed. You can set the address up to #16. (Address setting range: #1 ~ #16)
Entering to Address Mode
<Controller>
<Controller>
On
Off
Close
Open
<Interlock On>
<Interlock Off>
05
06
※ Rated load (for Output) : 0.5A at 30V DC
<Controller>
<Controller>
<Controller>
<Controller>
<Controller>
<Remote On>
<Power On>
<(Head Fail) Alarmed>
<Interlock On>
<(Over Time) Alarmed>
07
▶ Head Unit (SXH-10T)
▶ Controller Unit(SXC-10T / 102T / 104T)
7
Dimensions
8
Specification
08
※ The appearance and specification of the product may be changed without prior notice for the improvement of the product.
Parameter
Ion Generation Method
Source
Beam Angle
Input Power
1:1 Type
1:2 Type
1:4 Type
Controller Fuse
Operation Circumstance
SXH-10T
SXC-10T
SXC-102T
SXC-104T
Dimensions
Alarm Function
Power
Consumption
(with Head)
Weight
Head
Controller
Description / Value
Soft X-ray
Soft X-ray Tube
150˚(decay time within 1sec. at 100mm)
AC 100~240V, 50/60Hz
23W
40W
50W
250V, 3A, 5X20 Glass Type Fuse
0℃ ~ +50℃(32℉ ~ 122℉), 35% ~ 85% RH
0.29kg
0.47kg
0.60kg
0.88kg
Please Refer to Dimension Drawing
Head Fail, Head Communication error
1 year
(Run, Alarm, Power, Over Time, Remote, Interlock)
Remote On/Off, Interlock On/Off, Output State
Warranty
Interface
※ Run/Stop button is available only when you are not using the remote.
Press Run/Stop for 5 sec. after the controller is powered(Power LED On), you will be entering to the
address setting mode.
※ The entrance of address mode is enabled only if the interlock is in off condition.
Please check whether the interlock LED is set to off.
Assign Address
Address Setting
Once you get into the address mode, the address number sequentially changes from #01 to #16
when you press Run/Stop button promptly.
Wait for 5 sec. after assigning address, then your address is set correctly and automatically exits the
address mode.
< Address Mode >
<Side>
<Top>
<Rear>
<Front>
109.5
80.0
32.5
32.5
29.0
33.5
10.0
56.0
28.5
1/4 - 20 UNC
2-M4X0.7
If #4 and #5 of a D-Sub cable are connected, the interlock is on.
When LED is on, it shows that the door is securely locked and totally shielded.
"Interlock indicator ( )" light will be blink in the front of the controller.
If #4 and #5 of a D-Sub cable are disconnected, the interlock is off.
When LED is off, it shows that the door is securely unlocked and not shielded well.
"Interlock indicator ( )" light will be turned off in the front of the controller.
5
How to set
▶ Set the interlock
Interlock On
Interlock Off
<Controller Indicator Light>
<Controller Indicator Light>
Article
D-Sub Cable No.
State
Meaning
Controller Indicator Light
Interlock On
4 - 5 Close
The shield door is closed
Normal operation standby
On
Interlock Off
4 - 5 Open
The shield door is open
Abnormal operation standby
Off
Set-up interlock before setting remote. If the interlock is in off, the head unit will not operate even
though the remote is on.
If #2 and #3 of a D-Sub cable are connected, the remote is off.
Remote off indicates that the head unit is not operating.
▶ Set the remote
Remote On
Article
D-Sub Cable No.
State
Meaning
Remote On
1-3 Close
Head starts operating
Ion starts forming
Remote Off
2-3 Close
Head stops operating
Ion stops forming
<Controller Indicator Light>
<Controller>
Off
Close
<Remote Off>
<Controller Indicator Light>
<Controller>
On
Close
<Remote On>
▶ Output status signal
category
6-7 Close
Remote On
Ion Forming
14-15 Close
Power On
Power applied
(Over Time) Alarm
Status Output
(Head Fail)
Status Output
D-Sub
Cable No.
17-18 Close
21-22 Close
Status
(Over Time)
Alarmed
(Head Fail)
Alarmed
Meaning
Head Unit
Malfunction
Controller
Indicator
Run/Stop
Indicator On
Tube Replacement
Alarm Indicator On
Malfunction
Indicator On
9-10 Close
Interlock On
Remote
Status Output
Interlock
Status Output
Power
Status Output
Normal Operation
Standby
Interlock
Indicator On
Power
Indicator On
Head Unit:
7,500 Hrs of use
Remote Off
6
Problem solving
▶ Checklist before called
Problem
Identifying Problem
Solution
Not Operating
Please re-plug the power cable
and then turn the device on again.
Was the proper voltage level applied
for this set-up?
Please use the proper level of power
input for the device.
(AC 100~240V, 50/60Hz)
Is the swith off at back
of the Controller?
Turn on the power switch.
Is a fuse broken?
Replace the proper fuse immediately.
Is there any alarm LED on the
head unit of device?
Purchase and replace
the tube unit(replaceable).
Is remote off?
Clear the remote off corresponding
to 「Remote Setup」 manual.
Is Interlock off?
Check whether the cable connection
is properly done.
No Signal
Have you followed the proper procedure
for Input/output signal cable(s)
Place Interlock on corresponding to
「Interlock setup」 manual.
Decreased
Performance
Error code displayed on
the Controller LCD panel
Can't possibly ground the device?
Head unit not working
(when pressing Run
button on the controller)
Is the remote off control
on your machine?
See from manual for [Error code Verification].
Clear the Remote off
on your machine.
Is your power cable still plugged in?
Any damages or cut on the cables?
You need to replace the cables
if it gets cut or damaged.
Please refer to 「Installation & Connection」
for(proper) grounding the device.
Error Code
Status
Solution
Err 1
Err 2
Err 3
Err 4
Err 5
Check the connectivity of output cable
Check the status of head cable connection.
Replace the cable if head cable gets cut or damaged.
Turn the power off and restart it again..
Replace the power module of the head unit.
Contact us immediately.
Initial synchronization false
of head unit and controller
Disconnecting communication
error due to wire separation or
breakage of communication cable
Hours of head unit usage
information reception error
Ionization level of the head unit is
lower than the minimum current
An excess current detected when
the time change of head unit
Replace the tube module of the head Unit
Contact us immediately.
▶ Error code verification
1:1 Type
Controller
(SXC-10T)
1:2 Type
Controller
(SXC-102T)
1:4 Type
Controller
(SXC-104T)
162.5
181.0 ±0.5
66.0
12.0
106.0
6.0
41.0
52.0
193.0 ±0.5
174.5
200.5 ±0.5
66.0
12.0
116.0
6.0
41.0
52.0
212.5 ±0.5
253.5 ±0.5
41.0
52.0
215.0
241.5 ±0.5
66.0
12.0
131.0
6.0
Copyright 2018. SUNJE Hi-Tek Co., Ltd. All Rights Reserved.
Sunje (SHANGHAI) Trading Co.,Ltd.
Block C, 4F, No.482, Hongxu Road, Minhang District,
Shanghai, China
T) +86-21-5433-9761 F) +86-21-5433-9762
Sunje Technology Co., Ltd.
2F, No.6, Lane.102, Sinhe Rd, Sinfong Township,
Hsinchu County, Taiwan 30472
T) +886-3-568-7891 F) +886-3-568-7950
Sunje Japan Co., Ltd.
3-11-16-321 Higashimikuni, Yodogawa-ku, Osaka, Japan
T) +81-6-4866-5202 F) +81-6-6399-9290
Head Office & Factory (Busan)
8 ,Cheonggwang-gil, Ilgwang-Myeon, Gijang-Gun,
Busan, Korea
T) +82-51-720-7500 F) +82-51-720-7501
Southern Sales Office (Chilgok)
35-2, Seojungni 3-gil, Seokjeok-eup, Chilgok-gun,
Gyeongsangbuk-do, Korea
T) +82-54-476-9033 F) +82-54-476-9034
Central Sales Office (Hwaseong)
3F, Ilshin B/D, 4, Namnyeoul 2-gil, Hwaseong-si,
Gyeonggi-do, Korea
T) +82-31-203-9034 F) +82-31-202-9034
Customer Center
+82-70-7714-9033
Sales Contact
+82-31-203-9034
www.sunstat.com