6.9
Battery Connection
This section mainly describes the cable connections on the inverter side. Refer to the in-
structions supplied by the battery manufacturer for the connections on the battery side
and configuration.
Only use properly insulated tools to prevent accidental electric shock or short
circuits. If insulated tools are not available, use electrical tape to cover the entire
exposed metal surfaces of the available tools except their tips.
The plug connector must be connected only by trained electricians.
Do not disconnect under load!
Battery connectors must not be disconnected while under load. They can be
placed in a no load state by shutting down the inverter completely.
The hybrid inverter is not connected to a battery and does not support off-grid
operation functions.
6.9.1 Connecting the Power Cable
A fuse with the specification of 150 V / 125 A (type: Bussmann BS88 125LET) is inte-
grated to the B
BA
AT
T-- terminal.