15
3.2.4 Regular Operational Frequency Range
The inverter can operate within its frequency range for at least the specified observation
time. The setting of conditions depends on whether the connection is due to a normal
operational start-up or an automatic reconnection after tripping of the interface
protection.
When the frequency level is outside the operational levels, the inverter will disconnect
from the grid. If a disturbance lasts less than the required protection time, the inverter
can reconnect to the grid once the frequency level goes back to normal levels after the
disturbance.
3.2.5 Reactive Power Regulation
The inverter is capable of operating in reactive power regulation modes for the purpose
of providing support to the grid. The reactive power regulation mode can be set via the
iSolarCloud App.
3.2.6 Load Control
The inverter has an integrated multiple-function dry-contact (DO relay), which can be
used for load control via a contactor.
User may set the control mode according to individual demand.
•
T
Tiim
miin
ng
g M
Mo
od
de
e:: Set the starting time and end time. The DO function will be enabled
during the time interval.
•
S
Sw
wiittc
ch
h M
Mo
od
de
e:: The DO function can be enabled or disabled.
•
IIn
ntte
elllliig
ge
en
ntt M
Mo
od
de
e:: Set the starting time, end time, and the optimized power. During
the interval, when the export power reaches to the optimized power, the DO function
will be enabled.
3.3
Battery Management
Li-ion battery from SUNGROW, LG Chem and BYD are compatible with the PV ESS,
further battery models will be made compatible in the furture.
The currently supported battery brands and models are shown in the following table.
B
Brra
an
nd
d
M
Mo
od
de
ell
F
Fiirrm
mw
wa
arre
e V
Ve
errssiio
on
n
SUN-
GROW
SBR096/128/160/192
≥ SBRBCU-S_22011.01.05
LG
Chem
RESU7H_Type_R
DC-DC converter version ≥ 4.8
Battery management system (BMS)
version ≥ 1.7.0.1
RESU10H_Type_R
BYD
Battery-Box HV 5.1, 6.4, 7.7, 9.0,
10.2
≥ V3.013
User Manual