background image

Physical Dimensions

All dimensions have a tolerance of +/- 2 mm

Liability Limitation

Sunflare is not in control of the installation of the 

module and hence does not accept responsibility 

nor liability for damages arising from improper 

use, incorrect installation, operation, or 

maintenance of the product.

The information provided by this manual is based 

upon Sunflare’s knowledge and understanding 

and is believed to be correct and reliable. 

However, the customer is responsible for the 

installation, operation and maintenance of the 

product and any damage that might occur to 

the product or the roof as a consequence of 

those activities even if the customer followed 

guidelines and descriptions set forth in this 

manual. Sunflare takes no responsibility for 

material incompatibility between Sunflare 

components and non-Sunflare components, nor 

to any roofing products with which they may 

come in contact.

Sunflare accepts no liability for: damages, 

financial losses of any kind, business 

interruptions, or lost earnings, whether they be 

direct or incidental, as a result of the use of the 

information contained in these instructions, and 

whether or not they are based upon Sunflare’s 

negligence.

No suggestions, recommendations, power 

ratings, or any other guidance set forth in this 

document constitutes an expressed or implied 

warranty. Product warranties are not made in this 

document. Warranties are included in a separate 

warranty document, or through purchase 

agreements.

Revision History

Document
Sunflare_PowerFit20_Installation_instruction_V1
Sunflare_PowerFit20_Installation_instruction_V2
Sunflare_PowerFit20_Installation_instruction_V3

Date of Revision

06/07/2021
07/08/2021

09/20/2021

Contact Information

Sunflare Co.

1693 Yeager Avenue

La Verne, CA 91750 USA

Tel: 1-888-577-9935

Email: [email protected]

Web: www.sunflaresolar.com

13

1693.36±2 mm 
[66.7±0.1 in]

354.0±2 mm 

[13.9±0.1 in]

Summary of Contents for PowerFit20

Page 1: ...Installation Instructions for the PowerFit20 Photovoltaic Modules...

Page 2: ...ed to one side of the seam and allow for a clean wiring for each module to go to the roof cap This piece will be installed with the butyl based adhesive included with the component WMS Junction Box Co...

Page 3: ...re conduit This will allow for a more structurally sound install along with creating a water proof sealant to prevent debris from entering the WMS Other Required Components Inverters Consult your inst...

Page 4: ...e shall not be considered to comply with the requirements of UL1703 unless the module is mounted with hardware that has been tested and evaluated with the module under this standard or by field inspec...

Page 5: ...nd death Do not attempt to install service remove touch or modify a damaged module Damaged modules should only be removed by qualified professionals wearing appropriate personal protection equipment f...

Page 6: ...nt electricity from being generated Do not wear metallic jewelry including ear nose and lip rings watchbands pins or any other metallic object during installation or troubleshooting of photovoltaic sy...

Page 7: ...Management System WMS is certified as Class A over any Class A metal standing seam roofing constructions Metal Roof Manufacturer Approvals The PowerFit20 module is fully engineered to reduce stresses...

Page 8: ...e flat space Use a rubber wheeled roller to ensure the proper pressure is applied to the module Module Installation After the roof has been cleaned to the requirements above the components can be adhe...

Page 9: ...s that are opposite the side of the WMS wire conduit pieces Using the 7 5 MC4 jumper cables connect one end to the module located on the upward slope and run it through the WMS wire conduit towards th...

Page 10: ...de of the junction box cover should go over and around the WMS wire conduit to ensure a watertight seal Apply pressure to the junction box cover to complete the installation Repeat this process until...

Page 11: ...ions with the PowerFit20 modules No more than 6 modules should be connected in series to one AP Smart component Doing any more will result in failure of the PV system Figure 11 Shows the proper connec...

Page 12: ...eplace any WMS junction box cover that is damaged or significantly degraded If a module is damaged leave it in place Do not attempt to remove the module from the roofing surface unless it poses an ele...

Page 13: ...o any roofing products with which they may come in contact Sunflare accepts no liability for damages financial losses of any kind business interruptions or lost earnings whether they be direct or inci...

Reviews: