OPERATION

Open Top Burners

Lighting:

1 .  Open 1/4 turn pilot isolation valves .

2 .  Light pilots .

 .  Turn valve completely on . Burner flame should be 1/2 

inch (1mm), stable blue flame, and should impinge on 

the bottom of a pot placed on the ring grate .

Shut-Down:

1 .  Turn all valves to the “OFF” position .

2 .  If the unit is to be shut down for an extended period of 

time, close the pilot isolation valves .

CAUTION:  Should burner ignition fail within 5 seconds, 

turn the burner valve off and repeat steps 1 through 5 . If 

ignition continues to fail, consult your factory authorized 

service agency .

Standard Ovens

Lighting:

1 .  Remove oven bottom(s) .

2 .  Depress and hold the red reset button, located on the 

safety valve behind the kick panel below the oven door, 

while lighting the oven pilot . Continue to hold the reset 

button for at least 60 seconds after the pilot is lit . Release 

the button . If the pilot does not stay lit, wait five minutes, 

then repeat the procedure .

Shut-Down:

1 .  Turn all valves and thermostats to the “OFF” position, or 

lowest setting .

2 .  If the range is to be shut down for an extended period of 

time, close the in-line gas valve .

Re-lighting:

1 .  Turn all gas valves off .

2 .  Wait five minutes .

 .  Follow procedure under “

Lighting

” at left .

Summary of Contents for SX-6-26A

Page 1: ... 570 6 6 90 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB 1DQ ENGLAND Telephone 081 561 04 Fax 081 848 0041 Part 451558 02 29 08 2005 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR A...

Page 2: ...Part 4515558 02 29 08 Page ...

Page 3: ...ith Legs 6 Installing The Backguard Or Shelf 6 Ventilation Air 6 Statutory Regulations 6 Gas Connection 7 TESTING ADJUSTMENT 7 Testing 7 Adjustments 8 Pilot Adjustment 8 Burner Gas Air Adjustments 8 OPERATION 9 Open Top Burners 9 Standard Ovens 9 MAINTENANCE CLEANING 10 Exterior Finish 10 Stainless Steel 10 Oven Interior Porcelain Enamel 10 Open Top Burners 10 Cast Iron Top Grates 10 ...

Page 4: ...lation complies with national and local codes 29 737mm 13 13 16 351mm 3 76mm 3 4 NPT REAR GAS INLET 6 152mm 26 660mm 32 1 2 826mm 53 5 32 1350mm 3 7 16 87mm 11 1 2 292mm 33 1 8 841mm 17 3 8 441mm 3 4 NPT REAR GAS INLET OVEN INTERIOR HxWxD 13 1 2 x 26 1 4 x 22 343mm x 667mm x 559mm 36 914mm Width Depth Height Oven Interior Combustible Wall Clearance w Legs w o Legs Height Depth Width Sides Rear 36 ...

Page 5: ...r cove base it is shipped without legs Legs must be fitted to the oven when it is installed on a combustible floor 4 The type of gas and supply pressure that the equipment was set up for at the factory is noted on the data plate and on the packaging This type of gas supply must be used 5 Do not remove permanently affixed labels warnings or data plates from the appliance for this may invalidate the...

Page 6: ...djusted to level the appliance and to compensate for uneven flooring InstallingThe Backguard Or Shelf 1 Rear of range must be easily accessible 2 Place the backguard high shelf salamander or cheesemelter on the rear of the range slipping the support brackets into the openings in the burner box sides 3 Securely fasten the support brackets to the burner box sides with 4 14 x 5 8 Hex washer head type...

Page 7: ...nd connection check gas supply A The type of gas for which the unit is equipped is stamped on the data plate located behind the lower front panel Connect a unit stamped NAT only to natural gas connect one stamped PRO only to propane gas B If it is a new installation have the gas authorities check meter size and piping to assure that the unit is supplied with necessary amount of gas pressure requir...

Page 8: ...manifold pressure tap A properly adjusted air shutter will provide for a distinct blue flame over the entire port area of the burners when at full rate Pilot Adjustment All pilot adjustment valves are mounted on the range to manifold When properly adjusted it should neither lift of the burner nor should it show a yellow tip Burner Gas Air Adjustments Variations in field conditions or rough handlin...

Page 9: ... 5 If ignition continues to fail consult your factory authorized service agency Standard Ovens Lighting 1 Remove oven bottom s 2 Depress and hold the red reset button located on the safety valve behind the kick panel below the oven door while lighting the oven pilot Continue to hold the reset button for at least 60 seconds after the pilot is lit Release the button If the pilot does not stay lit wa...

Page 10: ...pers or knives as particles of the iron may become imbedded and rust STEEL WOOL SHOULD NEVER BE USED Oven Interior Porcelain Enamel NOTE Disconnect line cord if applicable from power supply before cleaning or servicing 1 Before cleaning oven interior remove all oven racks and guides Oven racks and guides can be cleaned with a mild soap and warm water or run through a dishwasher 2 The porcelain int...

Page 11: ...Part 4515558 02 29 08 Page 11 ...

Page 12: ......

Reviews: