background image

SXC205 

Rev. 01/12/05

Operating Instructions • Warning Information • Parts Breakdown

Nipple

Leader Hose

Whip Hose

Nipple

Filter

Air Supply

Regulator

Quick Coupler

Oiler

Drain Daily

Do Not Install

Quick Coupling

Here

Air Supply...

Tools of this class operate on a wide range of air pressures. It is 

recommended that air pressure of these tools measures 90 PSI at 

the tool while running free. Higher pressure (over 90 psig; 6.2 

bar) raises performance beyond the rated capacity of the tool, 

which will shorten tool life because of faster wear and could 

cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water 

in the air line will cause damage to the tool. Drain the air 

tank daily. Clean the air inlet filter screen on at least a weekly 

schedule. The recommended hookup procedure can be viewed in 

the above figure.
The air inlet used for connecting air supply has standard 1/4" 

NPT. Line pressure should be increased to compensate for 

unusually long air hoses (over 25 feet). Minimum hose diameter 

should be 3/8" I.D. and fittings should have the same inside 

dimensions and be tightly secured.

Operation...

When using the grinder be careful not to exert excessive force. 

Too much force may be hazardous if it causes the cutting tool 

spindle to bend or break.
The burning of the work piece or excessive speed reduction 

indicates too much force being applied. Changing to a free 

cutting tool may be better for the desired rate of speed and stock 

removal.
Avoid hazardous condition by making sure there is sufficient 

gripping force on the spindle of the cutting tool by placing the 

spindle 7/16” or more inside the collet.

Lubrication...

Lubricate the air motor daily with quality air tool oil. If no air line 

oiler is used, run a teaspoon of oil through the tool. The oil can 

be squirted into the tool air inlet or into the hose at the nearest 

connection to the air supply, then run the tool. The amount of oil 

to be used is 1 ounce. Overfilling will cause a reduction in the 

power of the tool.
Other factors outside the tool may cause loss of power or erratic 

action. Reduced compressor output, excessive drain on the 

air line, moisture or restrictions in air pipes or the use of hose 

connections of improper size or poor condition may reduce air 

supply. Grit or gum deposits in the tool may cut power and may 

be corrected by cleaning the air strainer and flushing out the 

tool with gum solvent oil or an equal mixture of SAE #10 oil and 

kerosene.

Limited Warranty...

SUNEX INTERNATIONAL, INC. WARRANTS TO ITS CUSTOMERS THAT THE COMPANY’S SUNEX TOOLS® 

BRANDED PRODUCTS ARE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS. 

Sunex International, Inc. will replace any SXC Series Air Tool which fails to give satisfactory service due to defective workmanship 
or materials. This product carries a ONE-YEAR warranty. During this warranty period, Sunex Tools will replace free of charge 
any part or unit which proves to be defective in material or workmanship.

Other important warranty information...

This warranty does not cover damage to equipment or tools arising from alteration, abuse, misuse, damage and does not cover 
any repairs or replacement made by anyone other than Sunex Tools or its authorized warranty service centers.The foregoing 
obligation is Sunex Tools’ sole liability under this or any implied warranty and under no circumstances shall we be liable for any 
incidental or consequential damages.

Note:

  Some  states  do  not  allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so 

the  above  limitation  or  exclusion  may  not  apply  to  you.  Return  tool  to  Sunex  Tools,  transportation  prepaid.  Be  
certain to include your name and address, evidence of the purchase date, and description of the suspected defect.
If you have any questions about warranty service, please write to Sunex Tools. This warranty gives you specific legal rights and 
you may also have other rights which vary from state to state. After the one year direct replacement warranty has expired, some 
service parts are available for purchase through normal Sunex Tools service options.

Shipping Address:

 Sunex Tools  •  315 Hawkins Rd.  •  Travelers Rest, SC 29690

Mailing Address:

 Sunex Tools  •  P.O. Box 4215  •  Greenville, SC 29608

Summary of Contents for SXC205

Page 1: ...silica from bricks and cement and other masonry products and arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particle...

Page 2: ...e motions or uncomfortable positions over extended periods of time may be harmful to your hands and arms Discontinue use of tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming use Place the tool on the work before starting the tool Slipping tripping and or falling while operating air tools can be a major cause of serious injury or death Be aware of excess hose le...

Page 3: ... 1 13 Lever 1 14 RS20814 Protecting Rubber 1 15 Housing 1 16 Bearing 696ZZ 1 17 Rear Plate 1 Ref Part DESCRIPTION QTY 18 Pin 2 19 Rotor Blade 4 20 Rotor 1 21 Cylinder 1 22 Cone Muffler 1 23 Bearing Spacer 1 24 Front Plate 1 25 Ball Bearing 608ZZ 2 26 Washer 1 27 Clamp Nut 1 28 Spindle 1 29 RS20635 Collet 1 4 1 RS20635A Collet 1 8 Optional 30 RS20636 Collet Nut 1 31 RS20833 Stop Spanner 14mm 1 32 R...

Page 4: ...er factors outside the tool may cause loss of power or erratic action Reduced compressor output excessive drain on the air line moisture or restrictions in air pipes or the use of hose connections of improper size or poor condition may reduce air supply Grit or gum deposits in the tool may cut power and may be corrected by cleaning the air strainer and flushing out the tool with gum solvent oil or...

Page 5: ...tos productos químicos están El plomo en las pinturas con base de plomo Sílice cristalina en los ladrillos y cemento así como en otros productos de albañilería Arsénico y cromio proveniente de la madera tratada con productos químicos Los peligros al exponerse a estos productos varía dependiendo de qué tan frecuentemente se hagan esos tipos de trabajos Si desea disminuir su exposición a estos produ...

Page 6: ...os Suspenda el uso de esta herramienta si sufre de alguna molestia siente hormigueo dolor Acuda al consejo de un médico antes de reanudar el uso de la herramienta Coloque la herramienta sobre la superficie de trabajo antes de hacer la funcionar Los resbalones tropiezos y caídas durante la operación de herramienta pueden ser la causa de una lesión grave o la muerte Manténgase alerta con el exceso d...

Page 7: ... excesivo en la tubería de aire la humedad o las restricciones en los tubos de aire o el uso de conexiones de manguera de tamaño incorrecto o en malas condiciones pueden reducir el suministro de aire Los depósitos de arenilla o goma en la herramienta pueden disminuir la potencia y pueden corregirse limpiando el cribador de aire y lavando a chorro la herramienta con aceite disolvente de goma o una ...

Page 8: ...imiques on compte le plomb des peintures à base de plomb la silice cristalline des briques et du ciment et d autres produits de maçonnerie et l arsenic et le chrome du bois traité chimiquement Les risques associés à ces expositions varient selon la fréquence et le type de travail Afin de réduire votre exposition à ces produits chimiques travailler dans un endroit bien ventilé avec de l équipement ...

Page 9: ...gées peuvent nuire à vos mains ou à vos bras Cesser d utiliser l outil lorsqu une sensation d inconfort de fourmillement ou de douleur survient Consulter un médecin avant de reprendre l utilisation Placer l outil sur la pièce à travailler avant de le mettre en marche Un glissement un trébuchement et ou une chute lors de l utilisation de l outil peuvent être des causes importantes de blessures grav...

Page 10: ...drainage excessif du conduit d air de l humidité ou des limitations dans le boyau d air ou l utilisation de raccords de dimensions inadéquates ou en mauvaise condition peuvent réduire l alimentation d air Des résidus d abrasif ou des dépôts accumulés dans l outil peuvent diminuer la puissance ceci peut être corrigé en nettoyant le filtre à air et en nettoyant l outil avec du solvant à l huile pour...

Reviews: