Input
W
895 / 1095
Rated current (RLA)
A
4.1 / 5.0
Locked rotor Amp (LRA)
A
30
Thermal protector
UP3QE0594-T56 (Internal)
Capacitor
30
µ
F / 440-450V
Refrigerant oil
ml
440
Evaporator coil
Number of rows
3
Tube pitch(a)x row pitch(b)
mm
22×19.05
Fin spacing
mm
1.6
Fin type (code)
Hydrophilic aluminum
Tube outside dia. and type
mm
φ
7.94 Inner groove copper tube
Coil length x height
mm
482×352
Number of circuits
4
Fan motor
Model
YDK30-6R
Brand
Welling
Input
W
68 / 56 / 50
Speed
r/min
620/530/465
Locked rotor Amp(LRA)
A
0.35
Capacitor
2.5
µ
F / 450V
Water pipeline
Water inlet pipe
DN20
Water outlet pipe
DN20
Drainage pipe
DN20
PT valve joint
DN20
Max. operating pressure
MPa (atm)
1.0 (10)
Heat exchanger
Dividing wall type heat exchanger
Solar heat exchanger
Water inlet pipe
DN20
Water outlet pipe
DN20
Heat exchanger
Stainless steel SUS316L
Dim.×Length
mm
22 × 10000
Max. operating pressure
MPa (atm)
0.7 (7)
E-heater
W
3000 × 1
Hot water yield
m
3
/h
0.086
Loading Quantity
20'/40'/40H
Pcs
21/45/45
Notes:
1.
The test conditions: outdoor temperature 15/12
℃
(DB/WB), inlet water temperature 15
℃
, outlet water
temperature 45
℃
.
2.
Sound pressure value test conditions: four side of the unit, distance is 1m, and height is 1m + half of the unit’s
height. The sound pressure level is following this procedure:
3.
The specification may be changed for product improvement, please refer to the nameplate.