Instruction and Operation Manual
SA-07-11-37 Rev Orig
12
Jan 2009
MAINTENANCE
Disassembling the LMV-802
The following procedures apply to all
configurations of the LMV-802 process pump.
Refer to he specification sheet to determine your
specific pump configuration and optional
equipment included. Disassembly should be
done only to the extent necessary for repair.
Parenthetical numbers in the text correspond to
item numbers in the parts list section.
Note: The following replacement parts will be
required as a result of pump
disassembly and seal housing removal:
PART
ITEM NO.
QTY.
Impeller Tab washer
5
1
O-Ring Repair Kit
--
1
Thermal Barrier Gasket
87A
1
STEP 1
Remove nuts (914A) from the pump casing
studs.
STEP 2
Remove the driver and seal housing from the
pump casing (1).
Note: Exercise care not to damage the inducer
(9) if one is installed.
Note: Use hoist and hooks to prevent personal
injury.