39
3.9 Taking the equipment off
Leave the polluted area before taking the equipment off.
• Take off the head top.
• Switch off the fan unit.
• Release the belt and remove the fan unit.
After use, the equipment must be cleaned and inspected.
See 4 Maintenance.
4. Maintenance
The person who is responsible for cleaning and mainte-
nance of the equipment must have suitable training and
be well acquainted with work of this type.
4.1 Cleaning
Sundström cleaning tissue SR 5226 are recommended
for daily care. At more thorough cleaning or decontami-
nation - proceed as follows:
• Assemble the plug kit. See 3.5 e.
• Use a soft brush or sponge moistened with a solution
of water and dishwashing detergent or the like.
• Rinse the equipment and leave it to dry.
N.B.
Never use a solvent for cleaning.
4.2 Storage
After cleaning, store the equipment in a dry and clean
place at room temperature. Avoid exposing it to direct
sunlight. The flow meter can be turned inside out and
can be used as a storage bag for the head top.
4.3 Maintenance schedule
The following schedule shows the recommended mini-
mum maintenance procedures required in order to en-
sure that the equipment is always in functional
condition.
Before After Annually
use use
Visual inspection
•
•
Performance check •
•
Cleaning
•
Change of fan gaskets
•
4.4 Spare parts
Always use genuine Sundström parts. Do not modify the
equipment. The use of non-genuine parts or modifica-
tion of the equipment may reduce the protective function
and put at risk the approvals received by the product.
4.4.1 To change the particle filters/
gas filters/combined filters
Change the particle filters at the latest when they are
clogged. The fan senses when this has occurred and
provides a warning as described in 3.6 under the
heading Operation/performance. The gas filters should
preferably be changed in accordance with a predetermi-
ned schedule. If no measurements are made on site, the
gas filters should be changed once a week or more fre-
quently if the pollutants can be smelt or tasted in the
head top.
Bear in mind that both filters/combined filters must be
changed at the same time and must be of the same type
and class. Proceed as follows:
• Switch off the fan unit.
• Unscrew the filter/combined filter.
• Release the pre-filter holder. Fig. 37.
• Change the pre-filter in its holder. Clean as
necessary.
• To release the particle filter SR 510 from the
adapter, proceed as follows:
o Grip the filter with one hand.
o Place the thumb of the other hand on the under-
side of the adapter at the semicircular gap.
Fig. 38.
o Then prise out the filter. Fig. 39.
• To release the particle filter SR 510 from the gas
filter, proceed as follows:
o Grip the gas filter with one hand.
o Insert a coin or some other flat object, e.g. the fil-
ter adapter, in the joint between the particle and
gas filters.
o Then prise out the filter. Fig. 40.
•
Fit new filters/combined filters. See 3.5 d.
4.4.2 To change the gaskets
The gaskets in the filter mountings of the fan unit prevent
polluted air being drawn into the fan unit. They must be
changed once a year or more frequently if wear or age-
ing is detected. Proceed as follows:
• Switch off the fan unit.
• Screw out the filters.
• The gasket has a groove all round and is fitted on a
flange below the threads in the filter mounting. Fig. 41.
• Remove the old gasket.
• Fit the new gasket onto the flange. Check that the
gasket is in place all round.
5. Parts list
Fig. 2.
Item Part
Ordering No.
No.
1. Hood SR 561
H06-5012
2. Hood SR 562
H06-5112
3. Hood SR 520 M/L
H06-0212
3. Hood SR 520 S/M
H06-0312
4. Hood SR 530
H06-0412
5. Face shield SR 540
H06-0512
6. Full face mask SR 200, PC visor
H01-1212
6. Full face mask SR 200, glass visor
H01-1312
7. Half mask SR 900 S
H01-3012
7. Half mask SR 900 M
H01-3112
7. Half mask SR 900 L
H01-3212
8. Welding shield SR 590
H06-4012
9. Helmet with visor SR 580
H06-8012
10. Welding shield/Helmet with visor
SR 584/SR 580
H06-8310
11. Hose SR 550
T01-1216
11. Hose SR 551
T01-1218
12. Hose SR 951
T01-3003
13. Twin hose SR 952
R01-3009
14. Gold-plated shield SR 587
R06-0824
15. Shield 2/3, EN 3 SR 588-1
R06-0825
15. Shield 2/3, EN 5 SR 588-2
R06-0826
16. Flow meter SR 356
R03-0346
17. Steel net disc SR 336
T01-2001
18. Asbestos kit SR 509
T06-0105
19. Storage bag SR 505
T06-0102
20. STD Standard battery, 2.2 Ah
R06-0108
21. HD battery, 3.6 Ah
T06-0101
21. Battery charger SR 513
R06-0103
22. Belt SR 508
R06-0101
Summary of Contents for SR 550
Page 134: ...134 9 2 3 1 4 7 5 6 1 11 10 8 12 ...
Page 136: ...136 5 6 8 100V 240V 50 60 Hz 7 3 4 20 C 40 C RH 90 10 C 55 C RH 90 600 hPa 1200 hPa ...
Page 137: ...137 80 1 2 3 100 9 10 11 12 13 14 2 1 ...
Page 138: ...138 19 18 15 16 17 2 1 2 1 max 15 SR 951 ...
Page 139: ...139 23 22 21 20 ...
Page 140: ...140 25 24 28 A B C D 26 27 ...
Page 141: ...141 33 34 175 l min 30 31 32 25 29 35 36 ...
Page 142: ...142 37 38 39 40 41 42 ...
Page 143: ...143 ...