43
• If you can smell or taste the pollutants.
• If you experience dizziness, nausea or other
discomfort.
Limitations
• The SR 500 EX ATEX/IECEx approval applies only
when all components are ATEX/IECEx approved.
Therefore, when purchasing spare parts and
accessories, always make sure of their proper
approval if the equipment is to be used in explosive
atmospheres.
• The protective films for the head tops are not
ATEX/IECEx approved and must not be used if the
equipment is to be used in explosive atmospheres.
• The battery must not be charged in explosive
atmospheres.
• The SR 500 EX must always be used with two
particle filters or two combined filters.
• If the user is exposed to very high work intensity, a
partial vacuum may occur in the head top during the
inhalation phase, which may involve the risk of
leakage into the head top.
• The protection factor may be reduced if the
equipment is used in surroundings in which high
wind speeds occur.
• Be aware that the breathing hose might make a loop
and get caught up by something in your surrounding.
• Never lift or carry the equipment by the breathing hose.
• The filters must not be fitted directly to the head top.
• Only use Sundström filters.
• The user should take care not to confuse the
markings on a filter to standards other than
EN 12941:1998 and EN 12942:1998 with classification
of the SR 500 EX fan unit when used with this filter.
2. Parts
2.1 Delivery check
Check that the equipment is complete in accordance
with the packing list, and undamaged.
Packing list
• Fan unit SR 500 EX, bare
• Battery SR 501 EX
• Belt SR 508 EX
• Filter adapters SR 511, 2x
• Particle filters P3 R, SR 510, 2x
• Pre-filters SR 221, 10x
• Pre-filter holders SR 512 EX, 2x
• Flow meter SR 356
• Battery charger SR 513 EX
• User instructions
• Cleaning tissue SR 5226
• Vaseline tube
• Plug kit
2.2 Accessories / Spare parts
Fig. 1.
Item
No. Part
Ordering No.
1. Hood SR 561
H06-5012
2. Hood SR 562
H06-5112
3. Hood SR 520 M/L
H06-0212
3. Hood SR 520 S/M
H06-0312
4. Hood SR 530
H06-0412
5. Hood SR 601
H06-5412
6. Hood SR 602
H06-5512
7. Face shield SR 540 EX
H06-6012
8. Face shield SR 570
H06-6512
9. Full face mask SR 200, PC visor
H01-1212
9. Full face mask SR 200, glass visor H01-1312
10. PU hose SR 550 for SR 200
T01-1216
10. Rubber hose SR 551 for SR 200
T01-1218
11. Helmet with Visor SR 580
H06-8012
12. Hose SR 541 for SR 540
R06-0501
13. O-ring for breathing hose
R06-0202
14. Flat gasket for hose SR 541
R06-0506
15. Flow meter SR 356
R03-0346
16. Belt SR 508 EX
R06-2148
16. Rubber belt SR 504 EX
T06-2150
16. Belt PVC EX
T06-2151
17. Leather belt SR 503 EX
T06-2149
18. Harness SR 552 EX
T06-2002
19. Battery SR 501 EX, 2,1 Ah
R06-2002
20. Battery charger SR 513 EX
R06-2003
21. Fan SR 500 EX, bare
R06-2001
22. Gasket for fan
R06-0107
23. Pre-filter holder SR 512 EX
R06-2023
24. Pre-filter SR 221
H02-0312
25. Pre-filter holder
R01-0605
26. Particle filter P3 R, SR 510
H02-1312
27. Filter adapter SR 511
R06-0105
28. Particle filter P3 R, SR 710
H02-1512
29. Gas filter A2, SR 518
H02-7012
30. Gas filter ABE1, SR 515
H02-7112
31. Gas filter A1BE2K1, SR 597
H02-7212
32. Combined filter
A1BE2K1-Hg-P3 R, SR 599
H02-7312
33. Storage bag SR 505
T06-0102
34. Steel net disc SR 336
T01-2001
35. Vaseline tube
R06-2016
36. Plug kit
R06-0703
3. Use
3.1 Installation
See also the user instruction for the head top.
3.1.1 Battery
New batteries must be charged before they are used
for the first time. See 3.2 Assembly.
3.1.2 Filters
The choice of filters/combined filters depends on factors
such as the type and concentration of pollutants. The
fan unit may be used with only particle filters or with a
combination of particle filters and gas filters.
The following filters are available for the SR 500 EX:
• Particle filter P3 R (PAPR-P3), model number SR 510.
Used with an adapter. Two filters are supplied with the
fan. Can be combined with a gas filter.
• Particle filter P3 R (PAPR-P3), model number
SR 710. Provided with a thread, and there is no need
for an adapter. Cannot be combined with a gas filter.
• Gas filter A2 (PAPR-A2), model number SR 518.
Shall be combined with a particle filter.
• Gas filter ABE1 (PAPR-ABE1), model number
SR 515. Shall be combined with a particle filter.
• Gas filter A1BE2K1 (PAPR-A1BE2K1), model number
SR 597. Shall be combined with a particle filter.
• Combined filter A1BE2K1-Hg-P3 R (PAPR-
A1BE2K1-Hg-P3), model number SR 599.
Summary of Contents for SR 500 EX
Page 41: ...41 9...
Page 186: ...186 2 3 3b 3c 4 5 6...
Page 187: ...187 11 7 12 8 9 10...
Page 188: ...188 15 16 14 13...
Page 189: ...189 18 17 19 20 21 22 23 24...
Page 190: ...190 25 26 27 29 28...
Page 191: ...Notes Notes...
Page 192: ...Notes Notes...
Page 193: ...Notes Notes...
Page 194: ...Notes Notes...
Page 195: ......