SunDanzer DCF400 User Manual Download Page 3

DCF400 User’s Guide 

 

 

 

 

Version: 04-06-22 

3 of 8  

• 

This appliance operates on 

12 or 24 Volts DC

 (Direct Current) only!

 

• 

Under no circumstances should this appliance be directly connected to an AC (Alternating Current) power 
source.

 

• 

Be sure that the appliance does not stand on the electrical supply cable. Also, be sure the electrical cable is not 
squeezed or bent when the appliance is being installed or moved. 

• 

Installation  work  and  adjustments  on  the  appliance  must  be  carried  out  by  qualified  personnel  only.    Work 
performed  by  persons  with  inadequate  technical  knowledge  may  adversely  affect  the  performance  of  the 
appliance, causing damage to the equipment, and void the warranty. 

• 

It is dangerous to make alterations or attempt to modify this product in any way.  Product alterations will void 
the warranty. 

During Use 

     

Do not store any containers with flammable vapors or liquids in or around the appliance, such as organic solvents, 

spray cans, gas cans, etc

.

 

Servicing 

• 

This product should be serviced by an authorized technician and only genuine spare parts should be used. 

• 

Under no circumstances should you attempt to repair the appliance yourself.  Repairs carried out by inexperienced 
persons may cause injury or serious malfunctioning of the appliance. Unauthorized work may void the warranty. 

At the end of the appliance life 

When  disposing  of  your  appliance,  use  an  authorized  disposal  site.    The  refrigerant  must  be  completely  drained  and 

collected by an authorized technician for recycling prior to disposal. Check with your local Environmental Agency for 
recommendations on recycling this appliance in your area. Remove the electrical connection wiring and also ensure that 
the lid is removed. 

INSTALLATION 

Unpacking and Cleaning 

Remove all packaging and securing tapes from the appliance.  If needed, wash the inside and outside of the 

appliance with lukewarm water and a mild soap or detergent.  Abrasive or corrosive cleaning agents, steel 
wool, scouring sponges, or chemical cleaning agents should not be used.  A sponge, soft brush or towel is 
recommended.  After cleaning, thoroughly rinse and dry.  You may want to leave the lid open allowing the 
compartment to ventilate for 20-30 minutes to get rid of residual odors.  

Positioning 

The area in which the appliance is to be installed must be relatively cool, dry, and suitably ventilated. The area 

must be protected against any beating rain and free of abundant dust.  To ensure proper function, the appliance 
must be placed horizontally on a flat, firm, and stable surface resting level on all four supports. The floor must 
be sufficiently strong enough to support a fully loaded cabinet. Use wood or metal shims to level the appliance 
if necessary. 

Do not place the appliance close to heat sources (heater, stove, boiler, chimney, etc.), and avoid prolonged 

exposure  to  direct  sunlight.    This  appliance  uses  the  exterior  walls  to  transfer  heat  from  the  inside  of  the 
cabinet.  Ensure that there is adequate space between the appliance and neighboring walls or large objects.  

minimum spacing of 3 inches (7.5cm) is highly recommended.

  This will provide sufficient airflow around 

the appliance resulting in more efficient operation and longer appliance lifetime. Always keep the air vent 
openings of the compressor housing cover free from dust and obstructions. 

ELECTRICAL DC CONNECTION  

The appliance should be left for 2 hours after positioning before it is turned on, to allow the refrigerant oil to settle.  If the 

appliance has been handled standing on its side or on end, it should be allowed to stand in the normal operating position 
for 12 hours before turning it on. 

Summary of Contents for DCF400

Page 1: ...SunDanzer DCF400 User s Guide SunDanzer 420 E Aviation Drive Tucson AZ 85714...

Page 2: ...rature approaches the appliance operating temperature the appliance will not function as it should If the room ambient temperature exceeds 100 F 38 C the appliance will not function as it should This...

Page 3: ...ION Unpacking and Cleaning Remove all packaging and securing tapes from the appliance If needed wash the inside and outside of the appliance with lukewarm water and a mild soap or detergent Abrasive o...

Page 4: ...ontroller coincides with the positive wire to the compressor and the negative terminal of the battery or charge controller coincides with the negative wire to the compressor The leads should be connec...

Page 5: ...the room ambient temperature exceeds 100o F 38o C the appliance will not function as it should The appliance will tend to run warmer and it may be necessary to turn the thermostat to a colder setting...

Page 6: ...warm water to melt the ice 6 Defrost water can be collected by placing a pan under the defrost drain on the exterior bottom front of cabinet 7 When defrosting is complete wash and dry the interior Be...

Page 7: ...e cold and it will take time to return to temperature Does the cabinet have adequate ventilation around the side walls allowing it to transfer heat properly See Installation Section The lid will not o...

Page 8: ...AR TO THE PRODUCT CAUSED BY ACCIDENT ABUSE MISUSE NEGLECT UNAUTHORIZED ALTERATION OR REPAIR OR IF THE PRODUCT WAS NOT INSTALLED IN ACCORDANCE WITH SUNDANZER PRINTED INSTALLATION AND OPERATING INSTRUCT...

Reviews: