16.0 Dip Switch Settings and Wiring
The dip switches are at the S1 location on the board.
A.
2-pump models
BREAKER
DIP SWITCH NUMBER
1
2
3
4
5
6
7
8
9
10
40A
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
50A*
OFF OFF ON
OFF OFF OFF OFF OFF OFF OFF
60A
OFF OFF OFF ON
OFF OFF OFF OFF OFF OFF
*50A is the factory default setting
B.
1-pump models
240V DOMESTIC
DIP SWITCH SETTINGS
S1 LOCATION
40A
50A
(factory default)
60A
1
2
3
4
5
6
7
8
9
10
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
1
2
3
4
5
6
7
8
9
10
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
1
2
3
4
5
6
7
8
9
10
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
120V/240V CONVERTIBLE
DOMESTIC DIP SWITCH SETTINGS
S1 LOCATION
15A
(factory default)
30A
40A
1
2
3
4
5
6
7
8
9
10
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
1
2
3
4
5
6
7
8
9
10
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
1
2
3
4
5
6
7
8
9
10
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
BREAKER
DIP SWITCH NUMBER
1
2
3
4
5
6
7
8
9
10
15A*
OFF ON
OFF OFF ON
OFF OFF OFF OFF OFF
30A
OFF ON
ON
ON
OFF OFF OFF OFF OFF OFF
40A
OFF ON
OFF OFF OFF OFF OFF OFF OFF OFF
*15A is the factory default setting (GFCI Cord)