U-SERIES LOW LEVEL PROGRAMMING
LINE 2
NEUTRAL
LINE 1
GROUND
WARNING - Secure wires as defined by the NEC and in compliance with any local codes in effect
at the time of installation. The system data label contains specific electrical information required for
installation. A wiring diagram is provide with every system and is located inside the control systems
hinged cover. The wiring diagram may contain “manufacturers notes” vital to your particular
installation. Typical 120-Volt and 240-Volt installations are depicted below.
Use the illustrations and instruction below to connect your input power wiring. Always refer to the
wiring diagram provided with your control (located inside the hinged cover) prior to connecting any
wires.
U-SERIES VOLTAGE CONNECTION
120-Volt
NEUTRAL
LINE 1
GROUND
Blue & White Neutral Wires Crimped Together
GROUND LUG PROVIDED
!
Connect input Neutral to White Wire (crimped together with Blue wire).
!
Connect Line 1 to Black Wire.
!
Connect Line 2 to Blue Wire.
!
Connect input Neutral to White Wire (crimped together with Blue wire).
!
Connect Line 1 to Black Wire.
240-Volt
BLUE
WHITE
BLACK
GROUND LUG PROVIDED
BLUE
WHITE
BLACK
The Low Level settings such as Current Settings (limiting heater activation for low amperage
systems), Single or Dual Speed Pump, Accessory (pump or blower) Configuration, Circulation
Pump, Temperature Display (Fahrenheit or Celsius) and Light Configuration may be accessed
directly from the spaside control.
Press and hold the Light Key for approximately 20 seconds, the first
parameter will appear. Use the Up/Down Arrow Key to adjust the setting.
Press the Light Key to change to the next parameter .
4
LIGHT KEY
Current Limiting:
HC = High Current (No Current Limiting)
*
LC = Low Current (heater will turn off with high speed pump or accessory
operation)
Pump 1 Configuration:
SP 1 = Single Speed
SP 2 = Dual Speed
*
Accessory Configuration:
BL 0 = Not Installed
BL 1 = Single Speed Pump 2 or Blower Installed
*
Circulation Pump:
CP 0 = No Circulation Pump*
CP 1 = Circulation Pump
Temperature Display:
Tu F = Fahrenheit
*
Tu C = Celsius
Light Configuration:
LI 1 = Single Intensity (On/Off)*
LI 2 = Two Intensities
* notes default setting
Note: If the error code “FLC” appears after programming simply cycle the power to
the control unit and the error should clear.