Page 39
To Correct Condition:
1. Verify water level is 1” below lowest pillow. Add water if
necessary.
2. Check for clogged/excessively dirty filter cartridge. See
section 11.1 (page 29-30).
3. Purge “air lock” from circulation pump intake by removing the filter
cartridge. Hold your garden hose over the filter wall fitting (with
grate) using a rag as a seal around hose end, then ask a helper to
turn on water for 30 seconds, then turn off. Reinstall filter cartridge
and check spa. See section 11.1 (page 29-30).
4. If problem persists, contact your authorized dealer.
13.6 Panel displays COL
Cool Condition - Temperature has dropped 20 °F (11 °C) below
the current set temperature. The pump and heater have been
activated to bring the temperature to within 15 °F (8 °C) of the
set temperature. No corrective action is required. Note: during
cold periods, you may consider increasing the number of filtration cycles.
13.7 Panel displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Main pump will operate to
circulate warm water through the plumbing until the spa is out
of danger.
13.8 Panel displays - - -
The safety “Watchdog” software has been triggered and the
spa is deactivated. A problem has been detected which could
cause damage to the spa or its components. Contact your
authorized dealer.