Disconnect the inlet supply hose clamp from the pool and 

connect it to the solar panel header that has the 90-degree 

PVC elbow and hose adaptor. The inlet supply hose is 

the one that sends the water back to the pool.

Connect the 6 foot hose (included in the kit) to the pool 

inlet supply using the included plastic clamp. Connect 

the other end of the hose to the elbow connector opposite 

the other hose going into solar collectors. If the solar 

collectors are not installed on a flat surface, make sure 

to feed the water from the pool to the lower of the two 

headers. You always should feed the solar panels from 

the lowest point in the system.

Remove the plug or rags you placed in the round outlet 

and inlet fittings inside the pool.

If you are located in a high wind area you may want to 

purchase galvanized stake kits to secure the solar panel 

headers to the ground. Available at Pool Heating Depot 

www.poolheatingdepot.com part # 60739.

INITIAL OPERATION

The two-way solar control valve determines if the 

water is going to flow through the solar collectors or 

bypass the solar collectors. The system is on when the 

handle on the control valve is positioned perpendicular 

to the solar panel headers (see photo).

Put the valve handle in the heating position and turn 

on the pool pump. Check all connections for leaks and 

tighten connections as necessary. As the water is fed 

from the pump to the solar system, it will push out any 

air in the system. This can be seen by bubbles shooting 

into your pool from the pool supply inlet. After about 5 

minutes the air bubbles should stop.  This means your 

system has been purged of air and ready for operation.  

If bubbles continue to be seen, recheck all connections 

and tighten clamps as necessary.

Schedule your pump to run during the hours the sun will be shining on the solar panels. Once the pool reaches the 

desired temperature, you can bypass the solar panels by turning the solar control valve handle, so it is parallel to 

the solar panel headers. During times of rain or cold cloudy weather you may want to bypass the solar system to 

not radiate heat from the pool water.

SOLAR VALVE IN HEATING POSITION

8

Summary of Contents for Above Ground Solar Pool Heating System

Page 1: ...HEAT PUMPS SOLAR POOL HEATING SYSTEMS SOLAR POOL HEATING SYSTEMS Installation Maintenance for Above Ground Pools ...

Page 2: ...re and Additional Items 3 4 Placement 5 Assembly Installation 5 8 Initial Operation 8 Maintenance 9 Winterizing Your Solar Heater 9 Trouble Shooting 9 Warranty 9 Customer Service Back Cover Email support poolheatingdepot com Customer Service 1 888 984 1238 239 789 1080 Installation Hot Line 1 888 938 6943 ...

Page 3: ...LWAYS EXERCISE CAUTION AND COMMON SENSE WHEN UTILIZING THEIR SWIMMING POOL AND OPERATING EQUIPMENT GENERAL INFORMATION This manual provides a detailed step by step procedure for the installation of a Sunburst Above Ground Solar Pool Heating System If the directions are followed correctly and only recommended Sunburst hardware and components are used the installed system should provide years of tro...

Page 4: ... Solar Control Diverter Valve Part 60551 Threaded End Cap 1 1 4 x 6 Hose with Clamps Part 60550 PVC Elbow 1 1 2 FPT Part 60552 Cuffed Adapter Part AG 200 60 6 1 1 4 x 6 Hose Included with Part 60553 Solar Control Valve Unions Included with Part 60553 Solar Control Valve Flanges Part 60691 1 60003 1 7 Hose and 2 Stainless Steel Hose Clamps 3 ...

Page 5: ...Part 17048 12 18104 51 744 BTU Add On Kit Part 60739 High Wind Stakes Kit 4 stakes Part AG WB5X14 Underlayment with Staples Optional Items Available at www poolheatingdepot com 4 ...

Page 6: ...5X14 ASSEMBLY INSTALLATION The base kit is boxed with the solar panels rolled up inside along with the solar control valve diverter valve and installation hardware Remove the strap from solar panels and unroll them allowing the collectors to relax in the sun 30 to 60 minutes Leave the protective end caps on the solar panels to prevent dirt grass bugs or other debris from getting inside the solar p...

Page 7: ...itioning the headers with the serial number label closest to your pool equipment Remove and discard the black protective end caps covering the threaded ends of the header pipes Wrap the threaded ends of the headers with Teflon tape provided as shown for a watertight seal Thread elbow connectors on the outside ends of the header with the label closest to the pool pump and filter as shown Be careful...

Page 8: ...he opposite header furthest away from the pool pump and filter and without the label thread black end caps on the outside ends as shown Be careful not to cross thread Slip the 7 inch hose with two stainless steel gear clamps over the inside headers on the end without the label Use a 5 16 nut driver or flat blade screwdriver to tighten the clamps on the header Make sure to place the clamps in betwe...

Page 9: ...r control valve determines if the water is going to flow through the solar collectors or bypass the solar collectors The system is on when the handle on the control valve is positioned perpendicular to the solar panel headers see photo Put the valve handle in the heating position and turn on the pool pump Check all connections for leaks and tighten connections as necessary As the water is fed from...

Page 10: ...panels as possible to prevent damage to the heater This can be done by simply removing the solar panels from the system remove the end caps and tilt the units up so that the water runs out When no more water flows from your heater it is ready for storage along with your other pool supplies accessories TROUBLE SHOOTING Pool size vs number of kits needed for heating Above Ground Pool Solar System Si...

Page 11: ...d the pool heating depot Pool Heating Depot 2213 Andrea Ln Suite 109 Ft Myers FL 33912 Phone 1 888 984 1238 239 789 1080 Installation hotline 1 888 938 6943 Email support poolheatingdepot com Website www poolheatingdepot com ...

Reviews: