20

21

WHAT IS SYSTOLIC PRESSURE AND DIASTOLIC 

PRESSURE?

WHAT IS THE STANDARD BLOOD PRESSURE 

CLASSIFICATION?

The blood pressure classification published by World Health Organizatiom (WHO) and 

International Society of Hypertension (ISH) is as follows:

When ventricles contract and pump blood out of the heart, 

the blood pressure reaches its maximum value in the 

cycle, which is called systolic pressure. When the ventricles 

relax, the blood pressure reaches its minimum value in the 

cycle, which is called diastolic pressure.

vein

relax

blood entering

Diastolic  

press

artery

blood discharging

Systolic

Only a physician can tell your normal BP 

range. Please contact a physician if your 

measuring result falls out of the range. 

Please note that only a physician can tell 

whether your blood pressure value has 

reached a dangerous point.

CAUTION

LEVEL / 

BLOOD PRESSURE

 (mmHg)

OPTIMAL

NORMAL

HIGH

NORMAL

MILD

MODERATE

SEVERE

SYS

<120

120 - 129

130 - 139

140 - 159

160 - 179

≥180

DIA

<80

80 - 84

85 - 89

90 - 99

100 - 109

≥110

Grade 3 hypertension (severe)

Grade 1 hypertension (mild)

Grade 2 hypertension (moderate)

An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is measuring the 

systolic and diastolic blood pressure. During each measurement, the monitor records all of the 

pulse intervals and calculates the average; if there are two or more pulse intervals, the difference 

between each interval and the average is more than the average value of ±25%, or if there are 

four or more pulse intervals, the difference between each interval and the average is more than 

the average value of ±15%, the irregular heartbeat symbol appears on the display when the 

measurement results are displayed.

IRREGULAR HEARTBEAT INDICATOR

The appearance of the IHB icon indicates that a pulse irregularity consistent with an 

irregular heartbeat was detected during measurement. Usually this is NOT a cause for 

concern. However, if the symbol appears often, it is recommended to seek medical advice.

Please note that this device does not replace a cardiac examination, but serves to detect 

pulse irregularities at an early stage.

CAUTION

Summary of Contents for TMB-1583-S

Page 1: ...Upper Arm Blood Pressure Monitor with Comfort Inflate Technology Instruction Manual Model TMB 1583 S Item 16985 Manual Version V1 0 Issue Date 2021 07 12...

Page 2: ...od Pressure Monitor is a digital monitor intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from 8 16 about 22 cm to 42 cm It is intended for indoor adult u...

Page 3: ...end medical treatment without asking a physician for treatment advice If you are taking medication consult your physician to determine the most appropriate time to measure your blood pressure Never c...

Page 4: ...0 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation Before use make sure the device functions safely and is in proper working condition DO NOT use the device...

Page 5: ...ee records in memory Current Time Time and date year month day hour minute I I Blood pressure level Indicates the blood pressure level H Hour The hour in the clock mode M Minute The minute in the cloc...

Page 6: ...pose of the batteries in fire Batteries may explode or leak Remove batteries if the device is not likely to be used for some time Worn batteries are harmful to the environment Do not dispose with hous...

Page 7: ...monitor is off press and hold SET to enter the mode for year setting 3When you reach the correct year press SET to confirm the entry 4 Repeat steps 2 and 3 to set the DATE FORMAT then set the MONTH an...

Page 8: ...Wait at least 3 minutes between measurements This allows your blood circulation to recover Take the measurement in a silent room Relax as much as possible and do not move or talk during the measuremen...

Page 9: ...ned to the first 1 record All other records are pushed back one digit e g 2 becomes 3 and so on and the last record 60 is dropped from the list NOTE The current measurement is 01 The corresponding dat...

Page 10: ...SUREMENT Measurements may be inaccurate if taken in the following circumstances Within 1 hour of eating or drinking Immediately after tea coffee or smoking Within 20 minutes of bathing While talking o...

Page 11: ...0 DIA 80 80 84 85 89 90 99 100 109 110 Grade 3 hypertension severe Grade 1 hypertension mild Grade 2 hypertension moderate An irregular heartbeat is detected when a heartbeat rhythm varies while the u...

Page 12: ...he same arm everytime PROBLEM DISPLAY CAUSE SOLUTION NO POWER Display will not light up Batteries are exhausted Replace with new batteries Batteries are inserted incorrectly Insert the batteries corre...

Page 13: ...F 104 F 5 C 40 C within 3 mmHg 0 4 kPa Pulse value 5 Normal working condition A temperature range of 41 F 104 F 5 C 40 C A relative humidity range of 15 to 90 non condensing but not requiring a water...

Page 14: ...ic Compatibility EN 60601 1 2 2015 IEC 60601 1 2 2014 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic disturba...

Page 15: ...ctromagnetic emissions Emissions test Compliance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3...

Page 16: ...430 470 GMRS 460 FRS 460 FM c 5k Hz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation b 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5...

Page 17: ...pm EST Monday Friday or contact us at info stareliteinc com Our customer service will be happy to assist you 2021 Sunbeam Products Inc All rights reserved Distributed by Star Elite Inc 1175 Place du F...