background image

 9

6. Installation of the cabinet

B. Ensure the "L" shaped mounting channel is 
positioned in front of the sash. The  bottom channel
of the cabinet should  be positioned in the track 
provided on the bracket assembly. Pull the window 
down until  it rests just behind the front of the "L" 
shaped mounting channel. 

See (Fig. 11).

 
A. Align one hole in the bottom of the cabinet with one 
hole in the bracket assembly. Secure the cabinet to the 
bracket using (3) 1/4" screws provided. Repeat the 
same procedure on the opposite side of the cabinet. 
See (

Fig. 10

).

C. Check to make sure that the cabinet is slanted
slightly downward on the outside. If necessary, 
re-adjust support bracket as shown in (

Fig. 7)

Fig. 10

1/4" Screws

Fig. 11

7. Secure Shutters

A. Carefully slide the air conditioner back into the 
cabinet.(Please seek assistance for this procedure).
B. Reinstall the slide-out-chassis security screws 
(removed earlier) on both  sides of the cabinet. 
See (

Fig. 12)

.

Secure the top of the frames to the window sash with 
(2) 3/4" screws. 

C. Now, secure bottom frame of shutters using one 
shutter clamp and one 3/4" screw on each side(

Fig. 12

). 

8. Reinstalling Front Panel Assembly

A. Position the front panel on the cabinet starting at the 
top. The front panel lock tabs must be inserted into the 
retaining slots in the cabinet. Repeat this procedure on 
all sides. 
B. Secure the front grille to the cabinet using the Philips 
screws removed earlier(

Fig. 1

).

Fig. 12

Installation instructions

Window Sash

"L"Shaped
Mounting
Channel

Seal

Coil

3/4" screws

Security Screw

"L"Shaped
Mounting
Channel

Seal 

F
HR

  FAN
SPEED

MODE

OFF

ON

/

TIMER

Airconditioner

WAIT THREE MINUTES 
BEFORE RESTARTING

Summary of Contents for SCA103RWB1

Page 1: ...User s Manual 10 000 BTU Room Air Conditioner Model SCA103RWB1 20060316...

Page 2: ...ontents Introduction Parts Identification Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Page 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Page 4: ...ou have selected Introduction Part Identification Remote control model Remote Control Exterior Air Inlet Power Cord Cabinet Air Outlet Fresh Air Vent Lever Control Panel Front Panel Interior Air Inlet...

Page 5: ...o the rating plate of your air conditioner Table 1 If the air conditioner has a serial plate rating of 115 volts and up to and including 7 5 amps the unit maybe on a fuse or circuit breaker with other...

Page 6: ...nstallation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of the har...

Page 7: ...for ample air circulation through the unit See Fig B The rear of the unit should be outdoors and not in a garage nor inside of a building Keep unit as far away as possible from obstacles and obstructi...

Page 8: ...er 1 4 screw For 10K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal t...

Page 9: ...l V slot 2 3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in...

Page 10: ...ters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the cabine...

Page 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Page 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Page 13: ...remaining time to turn off the unit for only 12 seconds then LED shifts to display set temperature If you press TIMER button within the 12 seconds OFF TIMER will be canceled If the ON TIMER is set the...

Page 14: ...ontrol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the Mid mode fan speed 6 Low BUTTON Used to select the Low mode fan speed 7 Auto BUTTON Used to select the Auto...

Page 15: ...A 1 5volt batteries Do not use rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim To operate the room air conditioner aim the remote control to the si...

Page 16: ...e front grill To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Page 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Page 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: