Ins tallation ins tructions

B ecause the compressor is located on the 
controls side of the unit (right side), this side
will be heavier and more awkward to manipulate.
Inadequate support on control side of the unit
can result in personal injury and damage to your
unit and property. T herefore, it is recommended 
to have someone assist you during the installation
of this unit.

F. Your unit was designed to evaporate condensation 
under normal conditions.  However, under extreme 
humidity conditions, excess condensation may cause 
the  base pan to overflow to the outside.
T he unit should be installed where condensation
run-off cannot drip on pedestrians or neighboring
properties.

1. S elect the B es t L ocation
A. Your room air conditioner was designed to 
fit easily into a single or double hung window.  However,
since window designs vary, it may be necessary to 
make some modifications for safe and proper
installation.

B . Make sure the  window and frame are structurally
sound and free from dry and rotted wood.

C . F or maximum efficiency, install the air conditioner
on side of the house or building which favors more 
shade than sunlight. If the unit is in direct sunlight, 
it is advisable to provide an awning over the unit.

D. P rovide sufficient clearance around the cabinet
to allow for ample air circulation through the unit.
S ee (F ig.2).  T he rear of the unit should be outdoors
and not in a garage nor inside of a building.
K eep unit as far away as possible from obstacles
and obstructions and at least 30" above the floor or 
ground. C urtains and other objects within a room
should be prevented from blocking the air flow.

E . B e certain the proper electrical outlet is within reach
of the installation.  Use only a single outlet circuit rated
at 15 amps. All wiring should be in accordance with
local and national electrical codes.

.

Awning

Window opening requirements
(s ee table below)

S ide
obstruction

G round

F ence,
wall, or
other
obstacle.

12" Min.

30" Min.

20" 
Min.

20" 
Min.

C AUT ION

!

!

F ig.2

Model

Model

5K -6K

5K -6K

21"  

21"  

35"  

35"  

36"   

36"   

22" 

22" 

17.7" *12.4" *15.7" 

17.7" *12.4" *15.7"  18.5" *13.7" *17.7" 

18.5" *13.7" *17.7" 

8K  

8K  

S ize

S ize

C abinet s ize
   (W*H*D) 

C abinet s ize
   (W*H*D) 

Min. Window
 opening  

Min. Window
 opening  

Max. Window
 opening

Max. Window
 opening

5

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for SCA052MWB1

Page 1: ...User s Manual 5 000 BTU Room Air Conditioner Model SCA052MWB1 20060323 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ation Introduction E lectrical S pecifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6 9 13 14 All manuals a...

Page 3: ...re starting This manual contains information for the installation and operation of your room air conditioner Cabinet E xterior Air Inlet Interior Air Outlet Control Knob Note The figures in this manua...

Page 4: ...s electrical and other technical data The rating plate is located on the right side of the unit If the air conditioner has a serial plate rating of 115 volts and up to and including 7 5 amps the unit...

Page 5: ...h use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting 2 5 S crews 8 Top Channel 1 factory installe...

Page 6: ...ir conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over the unit D Provide sufficient clearanc...

Page 7: ...tioner Fasten the curtains to the unit with screws Fig 2 Fig 3 3 Cut the adhesive backed seal strip the window width R emove the backing from the seal strip and attach the seal strip to the underside...

Page 8: ...ash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 Fig 6 Fig 7 About 5 L Bracket S eal 7 If storm window presents interference fasten a 2 wide wood strip to the...

Page 9: ...air circulation R ecommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting...

Page 10: ...located on the up center side of the air inlet grille and slide the air filter to the up To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air con...

Page 11: ...on an angle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexib...

Page 12: ...registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty information visit www su...

Reviews: