SECTION 1       IMPORTANT SAFETY INSTRUCTIONS

4

1.4  SPECIAL RECOMMENDATIONS

• Place the portable air conditioner in a level spot. Leave at least 20" (50.8 cm) between the 

unit and the wall.

• The plug should always be accessible after the unit is settled.
• In order to let the compressor work properly, always keep the portable air conditioner in 

a vertical position.

• Do not place the portable air conditioner near gas or any flammable liquids.
• Keep the unit far away from TVs or radios in order to avoid electromagnetic interference.
• Do not use any chemical sprays such as insecticides, painting or any flammable products near the unit. 

These chemical substances may interact with the plastic cabinet and warp it and cause 
electric interference. 

1.5  ELECTRICAL REQUIREMENTS

WARNING

Electrical Shock Hazard

Plug into a grounded (3-prong) outlet.

Do not remove ground prong.

Do not use an extension cord.

Failure to follow these instructions can result in death,

fire, or electrical shock.

In the U.S. only: If codes permit and a separate ground wire is used, it is mandatory that the
ground path is adequate.

Check with a qualified electrician if you are not sure if the portable air conditioner is grounded.

A three-wire, single-phase, 60Hz AC only, electrical supply is required on a separate circuit. See model
and serial label for circuit amperage required for your specific model. 

If the portable air conditioner has a serial plate rating 115 Volts and up to and including 7.5 Amps, 
the unit may conflict with a fuse or circuit breaker with other devices. 

HOWEVER, THE MAXIMUM AMPS OF ALL DEVICES ON THAT FUSE OR CIRCUIT BREAKER CAN NOT
EXCEED THE AMPS OF THE FUSE OR CIRCUIT BREAKER.

If the portable air conditioner has a serial plate rating of 115 Volts and greater than 7.5 Amps it 
must have its own fuse or circuit breaker, and no other device or unit should be operated on that 
fuse or circuit breaker.

NOTE: The label lists the BTU capacity, amperage, voltage and refrigerant charge requirements.

Summary of Contents for KY-25

Page 1: ...USER MANU AL GUIDE GUIDE D UTILISATION MODO DE EMPLEO 9 000BTU 9 000BTU Model KY 25 Y 9000 BTU PORTABLE DIGITAL AIR CONDITIONER WHITE METAL METAL BLANC METAL BLANCO Model KY 25 Y 9000 BTU PORTABLE DI...

Page 2: ...9 SECTION 4 INSTALLATION INSTRUCTIONS 4 1 PORTABLE AIR CONDITIONER INSTALLATION 10 4 2 ASSEMBLING THE AIR EXHAUST DUCT 10 4 3 INSTALLING THE DUCTS IN THE WALL 11 SECTION 5 OPERATING YOUR PORTABLE AIR...

Page 3: ...air conditioner follow these basic precautions Plug into an exclusive grounded 3 prong outlet Do not remove ground prong Do not use an adapter Use two or more people to move or install portable air co...

Page 4: ...nit is supported by four castors In the event of fire use Carbon Dioxide CO2 extinguishers Do not use water or powder extinguishers Please help us to help you This portable air conditioner has been de...

Page 5: ...lure to follow these instructions can result in death fire or electrical shock In the U S only If codes permit and a separate ground wire is used it is mandatory that the ground path is adequate Check...

Page 6: ...wer conductors in an appliance cord and interrupts the circuit as a predetermined level of leakage current Since an LCDI specifically can detect a current leakage flowing to ground it provides ground...

Page 7: ...ust duct for condenser side according to the installation instructions 1 8 UNPACKING YOUR PRODUCT PARTS Keep upright Figure 2 1 9 TECHNICAL SPECIFICATIONS Model Color Rate Cooling Capacity Voltage Fre...

Page 8: ...number You can find this information on the model and serial number label Please record the model and serial number information below Also record the purchase date of your appliance Model Number Seria...

Page 9: ...LS NEEDED 3 2 ACCESSORIES 1 Flat blade and Phillips screwdrivers 2 Gloves 3 Tape measure 4 Utility knife 8 Figure 5 1 Indoor terminal end 2 Exhaust duct 3 Window assembly kit 4 Main piece 5 Window kit...

Page 10: ...not handle with damp or wet hands Do not squeeze the cable or let it come into contact with a sharp surface Do not use the power cables to drag the unit Do not leave the cable in a tangled coil when i...

Page 11: ...nels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that the hole on the main piece is not covered by other pieces F Place the window kit in the...

Page 12: ...commended that you use the shortest possible length of hose Take care to prevent any kind of bend in the middle of the exhaust hose as this will trap hot exhaust air which will radiate back into the r...

Page 13: ...the fan speed High speed or Low speed 4 Up or Down Temperature or Time Changing Button Use these two buttons to set to your desired temperature The temperature unit can be on Fahrenheit or Centigrade...

Page 14: ...ments When the unit is OFF if it hasn t been set on Time Delay press the Timer button The unit enters Timer Program Also the will flash in Timer Set Display Window and the Timer Indicator will be on i...

Page 15: ...to your desired room temperature with the temperature ranges from 64 F 90 F 18 C 32 C Recommended temperatures are 80 F 84 F 27 C 29 C 5 Select the fan speed by pressing the Fan Button on either the r...

Page 16: ...be in Fan Only Mode when the room temperature is below 81 F 27 C It will operate in Cooling Mode when the room temperature is above 81 F 27 C TIMER ON PROGRAM SETTING How to set When the unit is off y...

Page 17: ...nected to it When the WATER FULL indicator light disappears the compressor will start to work again 5 3 OPERATING REMOTE CONTROL MODEL KY 25Y ONLY CONT D 5 4 WATER FULL INDICATION AND DRAINING DRAININ...

Page 18: ...4 WATER FULL INDICATION AND DRAINING CONT D NOTE The cooling efficiency of your unit will be affected if the Drain Hose or the Garden Hose is always attached to it The Drain Hose or Garden Hose must...

Page 19: ...A On a warm day turn the unit on in the FAN ONLY Mode for a couple of hours so that the inside can dry out completely B Turn off the unit and unplug the unit C Empty the residual condensated water by...

Page 20: ...cribed in the Installation Instructions The water tank is full LCDI plug has tripped Press the RESET button on the LCDI plug The time is set properly Check if Then Open the air inlet and outlet The ai...

Page 21: ...ormal The hot air discharging port is properly installed Install the hot air discharging port properly as instructed in this manual 7 4 THE UNIT TURNS ON AND OFF FREQUENTLY The outside temperature is...

Page 22: ...am Products Inc utilis e sous licence Fabriqu en Chine pour Star Elite une division de Elite Group Inc Quebec Canada H3B 3X9 2006 Sunbeam Products Inc funcionando bajo el nombre de Jarden Consumer Sol...

Reviews: