background image

SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER

16

TIMER-OFF PROGRAM SETTING:

How to set:

When the unit is on, after being set with the TIMER-OFF, the unit will stop after your set delay time.
1) Press 

the 

Timer Button

on the control panel      or on the remote control     .  Now the TIMER

INDICATOR “      “ will flash in the Timer Set Display Window, and the Timer Indicator on the
control panel will be on.

2)  Press the       “Down” button or the      “Up” button to change the delay time to your desired time.
3)  After a 10 second delay (not pressing on any buttons), the digits will change to display.  The Timer

Setting Process is complete.  Once some time has passed, the digits will decrease in 10 minute
increments.

How to cancel:

When the unit is set with TIMER-OFF, while the unit is on, first press 

Timer Button

on the control

panel      or on the remote control      to check the Timer setting and the Time digits will flash. Press
the 

TIMER button

again and the Timer Setting will be cancelled. The Timer Indicator on the control

panel will then turn off.

WATER FULL INDICATION:

Under normal temperatures, water will evaporate without the need to drain it from the unit.
The 

WATER FULL

indicator light will turn on during days of extreme humidity, when in Cooling Mode

or Soft-Dry Mode. When the 

WATER FULL

indicator light turns on, it means that the water reservoir is

full. The compressor will stop working, but both of the two fan motors will continue working. The unit
will drain excess water once a Drain Hose or Garden Hose is connected to it. When the 

WATER FULL

indicator light disappears, the compressor will start to work again.

5.3  OPERATING REMOTE CONTROL 

(MODEL KY-25Y ONLY) CONT’D...

5.4  WATER FULL INDICATION AND DRAINING

DRAINING:

Only in extreme humidity

1)  To add a Drain Hose or Garden Hose you must first stop the unit by turning it OFF. You must then

unscrew the Drain Cap on the Pump Drain before inserting the white Drain Hose (5’3”/1.61m)
provided with your unit. (Attentionthere may be some water behind the Drain Cap. Have a bowl
or receptacle ready to catch any runoff
). 
After connecting the Drain Hose to the inner spout (Fig.15) of the Pump Drain, ensure that the
other end is placed in a bucket or receptacle for gathering the excess water. Check the water level
in the receptacle to avoid any possibilities of leaking. 
Instead of the Drain Hose provided with your unit, you may also use a Garden Hose (in cases where
you require a distance longer than that provided by the Drain Hose). In this case screw the female
end of a Garden Hose to the outer threaded spout of the Pump Drain (Fig.16). After connecting the
Garden Hose, place the outer end outside of the house or in a convenient area where the excess
water can be safely expelled. 

2) Now, turn the unit ON and back to its previous setting (either COOLING or SOFT-DRY mode).  The

Pump Drain will begin to pump water out of the unit. (If using a water bucket, please check the
expelled water level to ensure that it does not over flow.)  Once the WATER FULL light indicator
turns off … the DRAIN cycle is complete.  At this point, turn OFF the unit, remove the Drain Hose or
Garden Hose and then turn the unit back ON and to its previous setting (COOLING or SOFT-DRY
mode).

Summary of Contents for KY-25

Page 1: ...USER MANU AL GUIDE GUIDE D UTILISATION MODO DE EMPLEO 9 000BTU 9 000BTU Model KY 25 Y 9000 BTU PORTABLE DIGITAL AIR CONDITIONER WHITE METAL METAL BLANC METAL BLANCO Model KY 25 Y 9000 BTU PORTABLE DI...

Page 2: ...9 SECTION 4 INSTALLATION INSTRUCTIONS 4 1 PORTABLE AIR CONDITIONER INSTALLATION 10 4 2 ASSEMBLING THE AIR EXHAUST DUCT 10 4 3 INSTALLING THE DUCTS IN THE WALL 11 SECTION 5 OPERATING YOUR PORTABLE AIR...

Page 3: ...air conditioner follow these basic precautions Plug into an exclusive grounded 3 prong outlet Do not remove ground prong Do not use an adapter Use two or more people to move or install portable air co...

Page 4: ...nit is supported by four castors In the event of fire use Carbon Dioxide CO2 extinguishers Do not use water or powder extinguishers Please help us to help you This portable air conditioner has been de...

Page 5: ...lure to follow these instructions can result in death fire or electrical shock In the U S only If codes permit and a separate ground wire is used it is mandatory that the ground path is adequate Check...

Page 6: ...wer conductors in an appliance cord and interrupts the circuit as a predetermined level of leakage current Since an LCDI specifically can detect a current leakage flowing to ground it provides ground...

Page 7: ...ust duct for condenser side according to the installation instructions 1 8 UNPACKING YOUR PRODUCT PARTS Keep upright Figure 2 1 9 TECHNICAL SPECIFICATIONS Model Color Rate Cooling Capacity Voltage Fre...

Page 8: ...number You can find this information on the model and serial number label Please record the model and serial number information below Also record the purchase date of your appliance Model Number Seria...

Page 9: ...LS NEEDED 3 2 ACCESSORIES 1 Flat blade and Phillips screwdrivers 2 Gloves 3 Tape measure 4 Utility knife 8 Figure 5 1 Indoor terminal end 2 Exhaust duct 3 Window assembly kit 4 Main piece 5 Window kit...

Page 10: ...not handle with damp or wet hands Do not squeeze the cable or let it come into contact with a sharp surface Do not use the power cables to drag the unit Do not leave the cable in a tangled coil when i...

Page 11: ...nels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that the hole on the main piece is not covered by other pieces F Place the window kit in the...

Page 12: ...commended that you use the shortest possible length of hose Take care to prevent any kind of bend in the middle of the exhaust hose as this will trap hot exhaust air which will radiate back into the r...

Page 13: ...the fan speed High speed or Low speed 4 Up or Down Temperature or Time Changing Button Use these two buttons to set to your desired temperature The temperature unit can be on Fahrenheit or Centigrade...

Page 14: ...ments When the unit is OFF if it hasn t been set on Time Delay press the Timer button The unit enters Timer Program Also the will flash in Timer Set Display Window and the Timer Indicator will be on i...

Page 15: ...to your desired room temperature with the temperature ranges from 64 F 90 F 18 C 32 C Recommended temperatures are 80 F 84 F 27 C 29 C 5 Select the fan speed by pressing the Fan Button on either the r...

Page 16: ...be in Fan Only Mode when the room temperature is below 81 F 27 C It will operate in Cooling Mode when the room temperature is above 81 F 27 C TIMER ON PROGRAM SETTING How to set When the unit is off y...

Page 17: ...nected to it When the WATER FULL indicator light disappears the compressor will start to work again 5 3 OPERATING REMOTE CONTROL MODEL KY 25Y ONLY CONT D 5 4 WATER FULL INDICATION AND DRAINING DRAININ...

Page 18: ...4 WATER FULL INDICATION AND DRAINING CONT D NOTE The cooling efficiency of your unit will be affected if the Drain Hose or the Garden Hose is always attached to it The Drain Hose or Garden Hose must...

Page 19: ...A On a warm day turn the unit on in the FAN ONLY Mode for a couple of hours so that the inside can dry out completely B Turn off the unit and unplug the unit C Empty the residual condensated water by...

Page 20: ...cribed in the Installation Instructions The water tank is full LCDI plug has tripped Press the RESET button on the LCDI plug The time is set properly Check if Then Open the air inlet and outlet The ai...

Page 21: ...ormal The hot air discharging port is properly installed Install the hot air discharging port properly as instructed in this manual 7 4 THE UNIT TURNS ON AND OFF FREQUENTLY The outside temperature is...

Page 22: ...am Products Inc utilis e sous licence Fabriqu en Chine pour Star Elite une division de Elite Group Inc Quebec Canada H3B 3X9 2006 Sunbeam Products Inc funcionando bajo el nombre de Jarden Consumer Sol...

Reviews: