(Pg. 13) 1141-2156A

R

IGHT

L

EFT

11

IMPORTANT! TO ENSURE PROPER GAS

FLOW, BURNER CONTROL VALVES MUST

BE "OFF" BEFORE OPENING THE GAS

CYLINDER VALVE.

79

G

AS

C

YLINDER

V

ALVE

T

YPE

1 N

IPPLE

O

UTLET

V

ALVE

27

A

C

YLINDER

NOT

INCLUDED

Summary of Contents for GrillMaster ST6501EPB

Page 1: ...HARDWARE SHOWN ACTUAL SIZE IN MANUAL FOR YOUR CONVENIENCE EXTRA HARDWARE MAY BE INCLUDED CYLINDER NOT INCLUDED WARNING THE EDGES OF SHEET METAL PARTS CAN CAUSE INJURY IF NOT HANDLED WITH CARE USE EXTR...

Page 2: ...FOLD THE LEGS AND SECURE WITH SIX SCREWS AS SHOWN IN STEPS 1 AND 2 WARNING Combustion by products produced when using this product contains chemicals known to the State of California to cause cancer b...

Page 3: ...Pg 3 1141 2156A FRONT BACK BACK JR JR 3 QTY JR JR 1 JR JR...

Page 4: ...Pg 4 1141 2156A FRONT BACK JR 3 QTY JR JR BACK JR 2 JR JR...

Page 5: ...BACK 49 48 SET THE GREASE DRIP PANS 48 ONTO THE CASTING AND SECURE WITH THE GREASE PAN HANGERS 49 48a 48a AFTER STEP 4 WITH THE GRILL IN THE UPRIGHT POSITION SLIDE THE GREASE PANS 48a INTO THE GREASE...

Page 6: ...H SCREWS JR 2 QTY TEST THE IGNITER A SPARK SHOULD APPEAR AT ELECTRODE TIP IF THE SPARK DOES NOT APPEAR CHECK THE WIRE CONNECTION TO THE IGNITER CHECK THE WIRE CONNECTIONS TO THE MAIN BURNER AND SIDE B...

Page 7: ...Pg 7 1141 2156A RIGHT END LEFT END 2 QTY FRONT 5 BACK RIGHT END RIGHT END JR JR SECURE WITH SCREWS JR TIGHTEN ALL EIGHT PRE ASSEMBLED SCREWS AT THIS TIME A B...

Page 8: ...1 LEFT 40 41 Set the SIDE BURNER GRID 41 on the side burner base matching tabs to the slots NOTE Turn side burner grid until it stops Before each use check to see that the side burner grid is secure A...

Page 9: ...55 VE VE WO WO Pg 9 1141 2156A RIGHT LEFT FRONT 7 2 QTY 2 QTY VE WO LEFT 55 WO A B...

Page 10: ...RIGHT LEFT 8 2 QTY 2 QTY 63 63 B Pg 10 1141 2156A SB SB DZ 58 59 DZ A DZ THE WINGNUTS MUST BE IN THIS POSITION FOR THE LID TO CLOSE CORRECTLY...

Page 11: ...GHT LEFT 65 66 PIVOT WIRES 65 66 TO CENTER THE RACK SLIGHTLY BEND THE PIVOT WIRES TO ADJUST FOR A TIGHT FIT HOOK THE TOP PIVOT WIRE INTO THE BOTTOM RACK AND BEND WIRE FOR A TIGHT FIT 9 A Step 1 Step 2...

Page 12: ...9 10 WARNING During assembly of grill and when attaching or replacing the L P gas cylinder insure that the gas supply hose is free of kinks and or damage and is at least 3 away from hot surfaces such...

Page 13: ...141 2156A RIGHT LEFT 11 IMPORTANT TO ENSURE PROPER GAS FLOW BURNER CONTROL VALVES MUST BE OFF BEFORE OPENING THE GAS CYLINDER VALVE 79 GAS CYLINDER VALVE TYPE 1 NIPPLE OUTLET VALVE 27 A CYLINDER NOT I...

Page 14: ...Pg 14 1141 2156A 12 2 QTY FRONT JR 20 JR THE CYLINDER CAN BE REMOVED FROM THE BACK OF THE GRILL 20 EMBOSS INDICATES THE TOP...

Page 15: ...er than Sunbeam or an authorized service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes Sunbeam shall not be liable for any incidental or consequent...

Page 16: ...X T R A H A R D W A R E M A Y BE I N C L U D E D P A R A S U C O N V E N I E N C I A P U E D E H A B E R P A R T E S E X T R A S P I C E S D E Q U I N C A I L L E R I E S U P P L M E N T A I R E S P O...

Page 17: ...ES BORDS DES PI CES DE M TAL PEUVENT BLESSER SI ELLES NE SONT PAS MANIPUL ES AVEC PR CAUTION TRE TR S PRUDENT IMPORTANT POUR ASSURER UN D BIT AD QUAT DU GAZ IL FAUT QUELES BOUTONS DE R GLAGE DES BR LE...

Page 18: ...os de la combusti n generados al usar este producto contienen sustancias qu micas conocidas por el Estado de California como causantes de c ncer defectos en el nacimiento u otros da os al sistema repr...

Page 19: ...Pg 3 1141 2156A JR JR 3 Qt Cdad JR JR 1 JR JR DEVANT ADELANTE ARRI RE ATR S ARRI RE ATR S...

Page 20: ...Pg 4 1141 2156A JR JR JR JR 2 JR JR 3 Qt Cdad DEVANT ADELANTE ARRI RE ATR S ARRI RE ATR S...

Page 21: ...U S DEL PASO 4 CON EL ASADOR EN SU POSICI N NORMAL DESLICE LA BANDEJA DE ACEITE 48a POR LOS GANCHOS DE SUJECI N VUE ARRI RE DU BARBECUE VISTA DE LA PARTE POSTERIOR DEL ASADOR 49 48 INSTALLER LES COLLE...

Page 22: ...ORDEMENT DU FIL L ALLUMEUR V RIFIER LE RACCORDEMENT DES FILS AUX LECTRODES DU BR LEUR PRINCIPAL ET DU BR LEUR LAT RAL V RIFIER LE BON FONCTIONNEMENT DE LA BATTERIE DE 9 VOLT PRUEBE LA IGNICI N DEBE AP...

Page 23: ...TR MIT DROITE EXTREMO DERECHO EXTR MIT DROITE EXTREMO DERECHO EXTR MIT DROITE EXTREMO DERECHO DEVANT ADELANTE ARRI RE ATR S FIXER AVEC LES VIS JR RESSERRER MAINTENANT LES HUIT VIS PR ASSEMBL ES SUJETE...

Page 24: ...ilise Chaque fois que vous l utilisez toujours v rifier que la grille de br leur lat ral est bien fix e en place Colocar la PARRILLA DEL QUEMADOR LATERAL 41 en la base del quemador lateral insertando...

Page 25: ...VE WO 55 GAUCHE IZQUIERDO A 55 VE VE WO WO 7 WO B Pg 9 1141 2156A 2 Qt Cdad 2 Qt Cdad GAUCHE IZQUIERDO DROITE DERECHO DEVANT ADELANTE...

Page 26: ...GAUCHE IZQUIERDO DROITE DERECHO B SB SB DZ 58 59 DZ A DZ POUR QUE LE COUVERCLE FERME CORRECTEMENT LES CROUS OREILLE DOIVENT TRE POSITIONN S DE CETTE FA ON LAS TUERCAS DE MARIPOSA DEBEN ESTAR EN ESTA P...

Page 27: ...ILLE INF RIEURE ET COURBER LA TIGE POUR BIEN L ASSUJETTIR PARA CENTRAR LA PARRILLA DOBLE LIGERAMENTE LOS ALAMBRES PIVOTE PARA AJUSTAR FIJAMENTE ENGANCHE EL ALAMBRE PIVOTE SUPERIOR EN LA PARRILLA INFER...

Page 28: ...ation en gaz n est pas entortill et qu il y a un d gagement d au moins 3 po entre le boyau et la coquille du barbecue ou toute autre surface chaude coquille du barbecue ou toute autre surface chaude P...

Page 29: ...LE IMPORTANTE PARA ASEGURAR QUE EL FLUJO DE GAS SEA APROPIADO LAS V LVULAS DE CONTROL DEL QUEMADOR DEBEN ESTAR CERRADAS OFF ANTES DE ABRIR LA V LVULA DEL TANQUE DE GAS GAUCHE DROITE DERECHA IZQUIERDA...

Page 30: ...2 Qt Cdad DEVANT ADELANTE LA BOUTEILLE PEUT TRE ENLEV E DE L ARRI RE DU BARBECUE EL TANQUE PUEDE QUITARSE DE LA PARTE TRASERA DEL ASADOR 20 LE RELIEF INDIQUE LA PARTIE SUP RIEURE EL ESTAMPADO EN RELI...

Page 31: ...ur tout dommage accidentel ou indirect ou pour bris de garantie expresse ou tacite en ce qui a trait ce produit ou certaines pi ces l exception o cette disposition soit interdite par la loi toute gara...

Page 32: ...o un centro de servicio autorizado Adem s la garant a no cubre desastres naturales tales como incendios inundaciones huracanes y tornados Sunbeam no se hace responsable de cualquier da o incidental o...

Reviews: