background image

natural gas supply 

piping system

6

7

Natural Gas 

Conversion

1-877-387-3639    |    Page 11

WARNING

instructions and all applicable codes and requirements of the Authority Having Jurisdiction. If the information 

proper installation of this kit. The installation is not proper and complete until the operation of the converted 

EN VERSION:

ANS Z21.97-2014 / CSA

Decorative Outdoor

Gas Firepit Table

2.41-2014
Outdoor Decorative Gas Appliances

MFG Date:

Series No.:

Model:

Manufacturer: Foshan Genux Metal Products Co.,Ltd
No.11 Beiwei Rd,Xihai Industrial Zone,Beijiao Town, Shunde District, Foshan City, Guangdong, China
Type of Gas: Natural Gas or Propane Gas

ORIFICE SIZE: NG=3.66mm, LPG=2.12 mm

LPG

NG

Manifold pressure for input Adj.

11.0In.w.c(2.7kpa)

7.0 In.w.c (1.7kpa)

BTU input

50,000 Btu/hr

50,000 Btu/hr

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide which has no odor. Using it
in an enclosed space can kill you. Never use this appliance in an enclosed
space such as a camper, tent, car or home.

Contact: Jay Trends Sales

1901 Aut. Transcanadienne, Dorval, QC H9P 1J1, Canada
Tel: 1-877-387-3639

WARNING

1.

Must not be used for cooking.

2.

The current configuration of the appliance is for
LP gas. If need to convert to NG use, please follow
the conversion instruction in manual.

3.

For outdoor use only. If stored indoors,
detach and leave cylinder outdoors.

4.

An LP-cylinder not connected for use shall not be
stored in the vicinity of this or any other
appliance.

5.

If do not keep a safe distant, it will raise up the
temperature of cylinder and cause explosion.

6.

Do not connect to a remote gas supply.

7.

The gas supply must be turned off at the LP-gas
supply cylinder when this appliance is not in use.

The instruction manual contains important

information necessary for the proper
assembly and safe use of the appliance.

Read and follow all warnings and instructions

before assembling and using the appliance.

Follow all warnings and instruction when

using the appliance.

If instructions or parts are missing, contact

1-877-387-3639.

Minimum clearance from sides and back of unit
to adjacent combustible construction: From top:
6Ft. (72

), From sides: 3Ft. (36

).

WARNING:

Improper

installation,

adjustment, alteration

service

or

maintenance can cause injury or property
damaged.

Refer to the owners information manual
provided with this appliance.For assistance
or additional information consult a
qualified installer, service agency or the gas
supplier.

WARNING: Do not store or use gasoline or

other flammable vapors and liquids in the
vicinity of this or any other appliance.An LP-
cylinder not connected for use shall not be
stored in the vicinity of this or any other
appliance.

CAUTION:The gas pressure regulator

provided with this appliance must be
used .This regulator is set for an outlet
pressure of 11 inches water column.

6. Retain the rating label for your records.

7. Perform Natural Gas Leak Test

(I) Make 2-3 oz. of leak test solution (one part liquid 

dishwashing detergent and three parts water).

(II) Apply several drops of solution where natural gas 

connection. If NO bubbles appear, the connections 

are secure. If bubbles appear, the connection has a 

leak, disconnect, reconnect, perform another leak test. 

If you continue to see bubbles after several attempts, 

the part is defective and should be replaced.

Summary of Contents for 9103-9294

Page 1: ... other appliance WARNING For outdoor use only WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the owner s manual thoroughly before installing or servicing this result causing property damage personal injury or loss of life CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed s...

Page 2: ...Do not operate unit until all parts are fully assembled Do not paint or color any part of this heating unit Unit may be hot while in use do not attempt to move it while in use Never leave this heating unit unattended while in use This unit is not intended for cooking Keep any flammable items away and do not use any other fireplace cover for this unit Keep a safe distance to avoid burning skin or c...

Page 3: ...able materials should not be hung from the appliance or placed on or near the appliance Any guard or other protective device removed for servicing the appliance shall be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning...

Page 4: ... any parts are missing or damaged do not attempt to assemble the product Tools Required for Assembly included Hex bolt driver Page 4 PART DESCRIPTION QUANTITY A Table Top With Burner 1 B Back Panel 1 C Side Panel 1 D Front Panel 1 E Bottom Tank Plate 1 F Door 1 G Adjustable Feet 4 H Flame Glass 17 6 lbs 1 Box I Protective Cover 1 J Lid 1 K Cross Bar 1 ...

Page 5: ...TION QUANTITY 1 Burner 1 2 Firebowl Pan 1 3 Ignition Pin 1 4 Thermocouple 1 5 Corrugated Pipe 1 6 LPG Reducer 1 7 Valve with LPG Hose and Regulator 1 8 Control Knob 1 9 Pulse Ignition 1 10 Heat Resistant Panel 1 11 Ignition Screen 1 12 Control Panel 1 13 NG Reducer 1 14 AAA Batteries 1 ...

Page 6: ...These precautions are necessary when using storing and servicing Using this appliance with the respect and caution demanded will reduce the possibilities of personal injury or property damage The following symbols shown below are used extensively throughout this manual Always heed these precautions as they are essential when using any mechanical or propane fueled equipment DANGER DANGER indicates ...

Page 7: ... with package contents list and hardware contents above If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Assembly 1 877 387 3639 Page 7 1 3 2 4 AA AA Washer Washer M6x30 Bolt M6x30 Bolt M6x25 Bolt x2 x2 x2 x2 x1 AA CC Washer M6x15 Bolt x2 x1 EE M6x25 Bolt x1 AA CC Washer M6x15 Bolt x2 x1 EE FF FF ...

Page 8: ...e information F E C D B AA EE EE AA BB A DD AA DD AA DD AA DD AA F E AA FF AA FF 7 Place table top A face down on flat surface Flip finished base and place on table top Assemble as indicated Page 8 5 7 6 AA AA Washer Washer M6x25 Bolt M6x30 Bolt Spring Washer x2 x2 x2 x2 x1 BB AA Washer M6x20 Bolt x4 x4 To continue assembly refer to page 12 FF EE DD ...

Page 9: ...e orifice from the bellows Propane orifice is painted with red mark propane hose propane orifice bellows gas valve propane orifice bellows Natural Gas Conversion 2 1 CAUTION Natural gas conversion must be performed only by a natural gas provider or service company 1 877 387 3639 Page 9 ...

Page 10: ...nnect the natural gas hose with the gas valve Requires a CSA Certified NG Conversion kit 50 000 BTU and 3 8 NG Hose by screwing clockwise tightly supply piping system Natural Gas Conversion natural gas supply piping system natural gas hose gas valve 3 4 5 inlet tube bellows Page 10 ...

Page 11: ...se explosion 6 Do not connect to a remote gas supply 7 The gas supply must be turned off at the LP gas supply cylinder when this appliance is not in use The instruction manual contains important information necessary for the proper assembly and safe use of the appliance Read and follow all warnings and instructions before assembling and using the appliance Follow all warnings and instruction when ...

Page 12: ...lace 11 Install Battery to Igniter 9 Remove the rubber cap on the electronic igniter A by unscrewing and slide battery B into the battery slot Make sure the positive side of the battery faces outwards Screw the electronic igniter cap A over the battery tightly 8 1 Leave adequate space around the Ignition Screen for ventilation 8 2 DO NOT block or cover the Ignition Screen with the flame glass Page...

Page 13: ... minimum hourly rate of 10 000 BTUs is required input rating for a fire table for automatic operation at rating less than full input rating The pressure regulator and hose supplied with the appliance must be used The installation must conform with local codes or in the absence of local codes with national fuel gas code ANSI Z21 97 2014 CSA 2 41 2014 natural gas and propane Installation Code CSA B1...

Page 14: ... E 13 A Install Cylinder Put the cylinder into bottom Plate E 13 B 13 C 13 C Close the door F Fire table assembly is now complete 13 A 13 B Secure the cylinder by tightening the screw in the bottom plate Page 14 ...

Page 15: ...ak test If bubbles continue appearing the hose should be returned to the place of purchase III If leak is at regulator cylinder valve connection disconnect reconnect and perform another leak test If you continue to see bubbles after several attempts cylinder valve is defective and should be returned to cylinder place of purchase If NO bubbles appear at any connection the connections are secure NOT...

Page 16: ... away from windows air intake openings sprinklers and other water sources 11 Fire table is at least 24 in on rear and sides from combustible materials and 62 in from ceiling 12 Fire table is on a hard and level surface 13 There are no signs of spiders or insects 14 All burner passages are clear 15 All air circulation passages are clear 16 Children and adults should be alerted to the hazards of hig...

Page 17: ...eing put into operation if it is evident that the burner Lighting 1 Make sure the control knob is in the OFF position Figure A 2 Fully open LP cylinder valve Note For initial start or after any cylinder change hold Control Knob IN for 2 minutes to purge air from gas lines before proceeding 3 Push in gas control knob turn counterclockwise to LOW Figure B and press the BLACK Ignitor button to light ...

Page 18: ...kly than normal Frequently check for corroded areas and repair them promptly Storage Between uses Turn Control Knob OFF Disconnect LP source protect exterior surfaces Note During periods of extended inactivity or when transporting Turn Control Knob OFF Disconnect LP source and move to a secure well ventilated location outdoors protect exterior surfaces Never leave LP cylinder exposed to direct sun...

Page 19: ...to prevent water from accumulating in the Firebowl Pan and to protect exterior surfaces direct contact with inclement weather such as rain sleet hail snow dust and debris CAUTION Firebowl Pan and Flame Glass are wet Page 19 ...

Page 20: ...laced under the Limited One 1 Year Warranty Policy are subject to a single claim Jay Trends will not be responsible for the installation labor or any other costs related to the re installation of a warranted part and such expenses are not covered by this warranty Jay Trends reserves the right to have its representative inspect any product or part prior to honoring any warranty claim Jay Trends sha...

Reviews: