Digital Blood Pressure Meter 7652
Digital display system/LCD 6 digits
Oscillometric method

Type AA batteries x 4

20-280 

 (Pressure)

40-200 Pulses/minute (Pulse)
- 3  

-5%

or 2% whichever greater (Pressure)

 se)

Automatic pressurization
Constant-Air-Release Valve System
Manual air release valve
Built-in memory enabling display of the previously measured value and

currents measurements.
To be automatically cut off after 2 minutes 30 seconds of 

 to

save energy.
Approx. 12 months with 3 min. usage per day
50” to 

 less than 85% RH

14” to 

 less than 85% RH

5”(W) x 3”(D) x 

13.0 

 (including 4 batteries)

Summary of Contents for 7652

Page 1: ...INSTRUCTION MANUAL Automatic Digital Blood Pressure Monitor Model 7652 Sunbeam Oster Household Products Before operating this unit please read these instructions completely P N 99944...

Page 2: ...ve arms or hands when measurement is being taken 2 DO NOT talk or chew when measurement is being taken 3 DO NOT take a series of measurements without waiting at least 10 minutes between measurements 4...

Page 3: ...sis of a single measurement See Fig 2 The blood pressure measured first thing in the morning after getting up before taking any food and with the subject still is known as the fundamental blood pressu...

Page 4: ...unced in hypertense patients Normally the blood pressure rises while at work and is at its lowest during the sleeping period The graph below illustrates the variations in blood pressure over a whole d...

Page 5: ...GRAM A Systolic blood pressure Diastolic blood pressure display section pulse display section Pressure setting switch Memory switch Start switch Power switch Hose connector Main kame Hose Plug Cuff ho...

Page 6: ...the pressure was insufficient Appears when the battery voltage is excessively low Appears when the blood pressure could not be obtained accurately Appears when the pulse rate could not be obtained acc...

Page 7: ...uff Wind the arm cuff around the left upper arm tightly for best results so that the bottom edge of the cuff is positioned one inch above the elbow joint Fig 4 Do not roll up a shirt or jacket It may...

Page 8: ...nd exhaust speed on the right side of the display Current Pressure Value gradually being reduced Exhausl Speed Measure Mark 2 When a pulse is detected the pressure value moves to the right side of the...

Page 9: ...hod Type AA batteries x 4 20 280 mmHg Pressure 40 200 Pulses minute Pulse 3 mmH 5 or 2 whichever greater Pressure Pu se 9 Automatic pressurization Constant Air Release Valve System Manual air release...

Page 10: ...eet 25 pack L Connector Above prices include shipping and handling Please print your name and address below Name Street Address City State Price 12 95 2 00 4 95 4 95 2 95 4 50 1 oo 3 95 4 95 Order 1 M...

Page 11: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state Warrantor Sunbeam Oster Household Products Sunbeam TM Health at Home 01992 Sunbeam Oster H...

Page 12: ...Above prices include shipping and handling Please print your name and address below Price 12 95 2 00 4 95 4 95 2 95 4 50 1 oo 3 95 4 95 Order 1 MODEL 7652 REPLACEMENT PARTS A N D A C C E S S O R I E S...

Reviews: