SPECIFICATIONS

EXPLANATION OF SYMBOLS

Model

HL858A2-LT

Internal power supply

DC 6V (4 x 1.5V AAA alkaline batteries)

DC 5V 1A (AC/DC Adapter) 

Measurement method

Oscillographic mode (inflation)

Measurement range of Cuff

Pressure 0 - 40kPa (0 - 300mmHg)

Measurement range of Determination

Pressure 5 - 39kPa (40 - 280mmHg)

Pulse value

40 - 199 beats/minute

Accuracy

Pressure ±0.4kPa (±3mmHg), Pulse value ±5%

Memory

2 x 120

Display mode

Liquid Crystal Display

Operating conditions

Temperature 41˚F - 104˚F (5˚C - 40˚C),  

Relative humidity 15% - 93%, Pressure 700 - 1060hPa

Storage & transportation conditions

Temperature -13˚F - 158˚F (-25˚C - 70˚C), Relative humidity ≤93%

Unit Dimensions

5.5” x 4.3” x 2.2” (L x W x H) 14cm x 11cm x 5.6cm (L x W x H)

Unit Weight

9.74oz ± 0.18oz (276g ± 5g) (Cuff and batteries excluded)

Cuff Size

UC-01: Standard size cuff 9 - 17” (23 - 43cm)

ELC-01: Extra large size cuff 17 - 22” (43 - 56cm)

Symbol

Explanation

Health & Life Information

Refer to instruction 

manual / booklet

TYPE BF Applied Part

To avoid inaccurate results caused 

by electromagnetic interference

Warning: Portable RF communications equipment (in-

cluding peripherals such as antenna cables and external 

antennas) should be used no closer than 30cm (12 

inches) to any part of the device, Otherwise, degradation 

of the performance of this equipment could result.

Waste of electrical and electronic 

equipment (WEEE)

Discard the used product to the recycling collection point 

according to local regulations.

Serial number

YYMMXXXXXX

Ingress Protection Rating

First characteristic numeral- Degree of protection against 

access to hazardous parts and against solid foreign objects 

N1=2 (Protected against solid foreign objects of 12.5mm 

Ø and greater) Second characteristic numeral - Degree 

of protection against ingress of water N2=2 (Protected 

against vertically falling water drops when ENCLOSURE 

tilted up to 15°)

Non-ionizing electromagnetic 

radiation

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there 
is no guarantee that interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment o and on, the user is encouraged to try to correct the interference by 
one or more of the following measures: 
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and the receiver.
•  Connect the equipment into an outlet on a circuit dierent from that to which the receiver 

is connected.

•  Consult the dealer or an experienced radio/TV technician for help. 

CAUTION:

To assure continued FCC compliance: Any changes or modications not expressly approved by 
the grantee of this device could void the user’s authority to operate the equipment.

RF EXPOSURE WARNING

1.  The equipment complies with FCC RF exposure limits set forth for an uncontrolled 

environment.

2.  The equipment must not be co-located or operation in conjunction with any other antenna 

or transmitter.

FCC LABEL COMPLIANCE STATEMENT:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.

HL858A2-LT ESSENTIAL PERFORMANCE PER IEC 80601-2-30 ADDITIONAL 

ESSENTIAL PERFORMANCE REQUIREMENTS:

•  201.12.1.102 Limits of the error of the manometer from environmental conditions. Over 

the temperature range of 41°F - 104°F (5°C - 40°C) and the relative humidity range of 
15% - 93%(non-condensing), the maximum error for the measurement of the CUFF 
pressure at any point of the NOMINAL measurement range shall be less than or equal to 
±3mmHg (±0.4kPa) or 2% of the reading, whichever is greater.

•  201.12.1.107 Reproducibility of the blood pressure determination.
The laboratory Reproducibility of the BLOOD PRESSURE DETERMINATION of the AUTOMATED 
SPHYGMOMANOMETER shall be less than 3mmHg (0.4kPa).

Summary of Contents for 16994

Page 1: ...1 Upper Arm Blood Pressure Monitor with Voice Broadcast Technology Instruction Manual Model HL858A2 LT Item 16994 Manual Version 001 Issue Date XX ...

Page 2: ...curate idea of your blood pressure MEASUREMENT METHOD HL858A2 LTAutomatic Upper Arm Blood Pressure Monitor measures blood pressure and heart rate by oscillometric method meaning the fluctuations in pressure are measured Once the cuff is wrapped around your upper arm just turn on the monitor and inflation automatically starts The inflation of the cuff creates pressure around the arteries inside upp...

Page 3: ...osis diabetes liver disease kidney disease severe hypertension peripheral circulation please consult your healthcare professional before using the device Blood pressure measurements taken with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method and are within the accuracy limits prescribed by the Standard of EN 1060 4 If the cuff is wor...

Page 4: ...perly BP Category Indicator The arrowhead points out the specific BP Category that your measurement reading fits in Average of Last 3 Measurements ThissymbolappearswhenLCDdisplaysaverage value of last3readings IRREGULAR HEARTBEAT DETECTOR The symbol will appear on screen indicating a certain heartbeat irregularity was detected during measurement The heartbeat rhythm that is more than or less than ...

Page 5: ... Insert 4 new AAA 1 5 V LR03 alkaline batteries into the compartment as shown Make sure the polazrities and align with the symbols inside the compartment 3 Replace the batteries when The low battery icon appears The display is dim or does not turn on Do not mix new and used batteries Do not mix alkaline standard carbon zinc or rechargeable cadmium batteries Such action may shorten the battery life...

Page 6: ...uff inanyway MEMORY FUNCTION 1 Themonitorfeaturesmemorystoragewithdateandtimestampsfortwo 2 users saving 120recordsperuser 240total 2 Aftereachmeasurement thesystolicanddiastolicpressure heartrateandBPCategory Indicator IrregularHeartbeatDetectorandExcessivebodymotiondetector if any withthe dateandtimewillbeautomaticallystored Eachnewreadingwillreplacetheoldest TAKING THE MEASUREMENT 1 With the cu...

Page 7: ...ol The cuff was wrapped incorrectly for example too loosely or too tightly Please reference applying the Cuff section to wrap the cuff correctly Note If EP appears on the display just return the device to your local distributor or importer RECALLING DATA 1 Press buttontoselectUser1or2 2 PressM buttontoenterMemoryMode If thereisnodatastored nothing exceptmonth date andtime willappearonthedisplay If...

Page 8: ...hthelimitsforaClassBdigital device pursuanttoPart15of theFCCRules Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation Thisequipmentgenerates usesandcanradiateradiofrequencyenergyand if notinstalledandusedinaccordancewith theinstructions maycauseharmfulinterferencetoradiocommunications However there isnoguaranteethatinterferencewillnotoccurinapar...

Page 9: ...15kV air discharge In the case of air discharge testing the climatic conditions shall be within the following ranges AmbientTemperature 15 C 35 C Relative Humidity 30 60 Power frequency 50 or 60Hz magnetic eld IEC 61000 4 8 30A m 50 or 60Hz 30A m 50 or 60Hz Powerfrequency magnetic eldsshouldbeatlevels characteristicof atypical locationinatypicalcommercial orhospitalenvironment Electrical fast tran...

Page 10: ...ed by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80MHz and 800MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures object...

Page 11: ...399 8 30 am 5 00 pm EST Monday Friday or contact us at info stareliteinc com Our customer service will be happy to assist you 2021 Sunbeam Products Inc All rights reserved Distributed by Star Elite Inc Montreal Canada H3B 3X9 SE005 080621 Upper Arm Blood Pressure Monitor Model HL858A2 LT Printed in China ...

Reviews: