Page 21 of 24
UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.3
Mains supply
–
Heat batteries with electrical input from solar diversion controller
Run and connect heater power supply cable (16A, minimum 2.5mm
2
CSA) from the solar diversion unit to the heat battery
controller as shown in figure 6.3.
•
Brown (Live):
Terminal 4 (Live)
•
Blue (Neutral):
Terminal 5 (Neutral)
•
Green/Yellow (Earth): Terminal 6 (Earth)
The control circuit power supply can be run from the same local isolator supplying the solar diversion unit.
A separate 6A supply should be used for the control circuit if there is a primary external heat source connected.
Set the controller program to type 1 for this application OR Type 2 if there is a primary external heat source connected
Figure 6.3: Wiring for heat batteries with solar diversion controller
Power supply
230VAC 16A
Heat battery