sun valley MSTBVN Owner'S Operation And Installation Manual Download Page 24

24

CAST IRON STOVE AND BURNER SYSTEM

107281

SUN VALLEY STOVE COMPANY

For more information, visit www.desatech.com

OBSERVED PROBLEM

Burner does not light after pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Heater produces a whistling noise when
burner is lit

Glass soots

Burner system produces a clicking/ticking
noise just after burners are lit or shut off

Remote does not function

REMEDY

1. Clean burner (see Cleaning and

Maintenance, page 22) or replace burner
orifice

2. Contact local propane/LP or natural gas

company

3. Reconnect leads (see Wiring Diagram,

page 26)

4. Replace thermopile

1. Contact local propane/LP or natural gas

company

2. Clean burner (see Cleaning and Main-

tenance, page 22) or replace burner orifice

1. Clean burner (see Cleaning and

Maintenance, page 22) or replace burner
orifice

2. Replace damaged burner
3. Replace gas control

1. Problem will stop after a few hours of

operation

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane/LP or natural gas company

3. Clean burner (see Cleaning and

Maintenance, page 22) or replace burner
orifice

1. Adjust the log set so that the flame does

not excessively impinge on it

2. Inspect the opening at the base of the

burner to see that it is NOT packed with
any type of material

1. This is common. If noise is excessive,

contact qualified service person

1. Replace 9-volt batteries in receiver and

remote control

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnected or im-

properly connected

4. Thermopile is defective

1. Manifold pressure is too low

2. Burner porting or orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Residues from manufacturing processes

and logs curing

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Dirty or partially clogged burner orifice

1. Flame impingement on logs

2. Debris around burner air mixer

1. Metal expanding while heating or con-

tracting while cooling

1. Battery is not installed or battery power

is low

www.desatech.com

Summary of Contents for MSTBVN

Page 1: ...installationand operational procedures For as sistance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not foll...

Page 2: ...perlyseatedandsealed If this unit is not properly installed by a quali fied service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs of car...

Page 3: ...gandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electricity making it ideal for emerge...

Page 4: ...ined see Figures 3 and 4 4 This stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other...

Page 5: ...e Figure 7 Rest stove on drop cloth orblankettoavoidscratchingstoveedges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adjustable wrench to remove bolts 8 Fasten...

Page 6: ...on a protected surface Remove the two screws that hold the front plate onto the front surround plate see Figure 14 Save these screws 15 Remove the seven screws and washers that hold the screen onto th...

Page 7: ...nector plate over gasket and align holes Secure with hex screws provided see Figure 17 IMPORTANT Gasketandconnectingplate must not be installed until after burner sys tem has been inserted into stove...

Page 8: ...hlocknutbypushingand turning lock nut with pliers clockwise until tight against the side of rear cover Place control knob provided onto shaft 7 Placethegreen ground wirebetweenthe bottom hole on the b...

Page 9: ...e 8 Make sure that you don t pinch any wires during reassembly Blower Power Cord ON OFF Switch Wire Harness ON OFF Switch Figure 22 Control Valve Terminals To Control Switch INSTALLATION PRECAUTIONS C...

Page 10: ...tion to select the correct gas vent di ameter Avoid using a larger than nec essary diameter It is very important that the venting system maintain its balance between the combus tion air intake and the...

Page 11: ...nt ing applications NOTICE A complete chimney inspection by a qualified person should be performed Appliances using B vent connectors to vent into a masonry or factory built chimney should not exceed...

Page 12: ...nd windows and or noticeable odors Spillage may also result in the release of carbonmonoxide acolorless odorless highly toxic gas A simple spillage test can be con ducted if spillage is suspected See...

Page 13: ...exposed to extremely cold tem peraturesorventingofsinglewallconstruc tion loses heat needed to maintain draft massive masonry chimneys absorb needed heat Ifthefluegasescoolexcessively draft is reduced...

Page 14: ...Valve Provided by Installer Equipment Shutoff Valve To Gas Supply Natural Figure 32 Attaching Flexible Gas Lines Together Figure 31 Gas Connection The CSA AGA design certified equipment shutoff valve...

Page 15: ...to all gas joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Burner System Gas Connections 1 Open equipment shutoff valve see Fig ure 33 2 Open propane LP supply tank valve...

Page 16: ...ch side of the base see Figure 37 WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur Figure37 BackViewofThermostatBase Feed wires through rectangul...

Page 17: ...g Receiver Battery Clip Terminal Wires LO H I P I L O T OFF ON Figure 40 Installing Remote Receiver 2 Remove the screws from the 2 tabs at the top of the glass door while holding door securely keeping...

Page 18: ...ury INSTALLING LOGS LAVA ROCK AND GLOWING EMBERS STOVE AND B VENT BURNER SYSTEM INSTALLATION Continued 1 2 3 4 Figure 45 Installing Log No 1 Figure 46 Installing Log No 2 Figure 47 Installing Log No 3...

Page 19: ...push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a f...

Page 20: ...will remain lit GHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 53 The lights to the left of the button will show AUTO ON or OFF Figure52 Settingthe...

Page 21: ...AL BLOWER ACCESSORY Blower controls are located on the left side of the rear cover of stove from front of stove The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting Th...

Page 22: ...WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute materials m...

Page 23: ...ot fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located...

Page 24: ...for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner or...

Page 25: ...l valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odor...

Page 26: ...elallwiresprior to disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswi...

Page 27: ...epartment at 1 877 SUNVAL1 for information You canalsowritetotheaddresslistedontheback page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access to the operation...

Page 28: ...UN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSTBVN MSTBVP LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 5 11 8 1 9 25 4 13...

Page 29: ...13 105489 01 Valve Natural 1 105489 02 Valve Propane LP 1 14 105488 01 Pilot Assembly Natural 1 105488 02 Pilot Assembly Propane LP 1 15 102445 01 Ignitor Piezo 1 16 106854 01 4 Connector Gasket 1 17...

Page 30: ...107281 SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates Color Suffix Designation 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5...

Page 31: ...lain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55...

Page 32: ...be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE D...

Reviews: