START UP & TEMPERATURE
REGULATIONS
1) START UP
a)
Turning the power on, the red indicating light on the
temperature control panel will light up
(See Figure 4 on
page 5)
, and the compressor will start up. The machine
will begin to refrigerate/freeze.
b)
The protection signal of the controller is a green
indicating light. It will flash a number of times if error
occurs. Count the number of flashes and compare with
the chart below:
(The module will operate at higher than desired temperatures if
the unit system has been overloaded or if the ambient temperature
is higher than 55°C/131°F. To ensure the longevity of the appliance,
please ensure that the unit is not overloaded and stored in an
environment where the ambient temperature is lower than
55°C/131°F)
c)
The unit will not run if there is an error in connecting the
anode (positive) and cathode (negative) voltage connectors.
2) TEMPERATURE REGULATIONS
The temperature will gradually drop when the knob of the thermostat
is turned clockwise and will gradually gain when the knob is turned
counter-clockwise. For the longevity of the appliance, it is not
recommended to leave the temperature dial at the coldest setting for
prolonged use.
GENERAL ISSUES &
TROUBLESHOOTING
1)
In case of an abnormal operation, please refer to the
Troubleshooting chart shown on page 8 for
inspection and possible solutions. If the issue cannot
be solved, please contact the service department of our
company or our local institutions with special
engagement.
The following are NOT results of faulty equipment:
1)
The condenser in the corresponding internal wall will
make the external condenser feel hotter than normal.
2)
The intermitting noises heard in the cabinet during the
operation of the unit after the compressor shuts down is
caused by the circulating flow of coolant in the
condensing pipes.
3)
The surface temperature of the compressor may rise to a
range between 70°C/150°F and 90°C/194°F.
4)
The condensed water beads on the external side of the
unit or door during the rainy seasons will not affect the
operation of the unit. The water beads may be wiped off
with a dry cloth.