Chapter 7
Service
7-19
8. Remove and replace the disk drive backplane (
FIGURE 7-17
Removing a Disk Drive Backplane
9. Reverse the previous steps to reassemble the disk array.
7.2.11
Interconnect Assembly
Note –
Rackmounted disk arrays must be removed from a cabinet before replacing
an interconnect assembly. See Section 7.2.12 “Removing a Rackmounted Disk Array”
on page 7-26 for removal instructions.
Caution –
The interconnect assembly is not a hot-plug item. You must remove
power to the disk array before replacing the interconnect assembly.
The disk array interconnect assembly contains the world wide number (WWN) of
the disk array. The WWN is used by the SCSI Enclosure Services (SES) software to
communicate with the disk array and obtain enclosure and environmental status. If
the interconnect assembly is replaced, the WWN will change and SES will no longer
see the disk array. Therefore, the
luxadm
command must be used to update the
software.
Summary of Contents for STOREDGE A5000
Page 12: ...xii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 17: ...Contents xvii D 6 2 sf Driver Software Errors D 15...
Page 18: ...xviii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 22: ...xxii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 26: ...xxvi Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 38: ...2 6 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 40: ...3 2 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 68: ...5 16 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 76: ...6 8 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 112: ...8 8 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 116: ...A 4 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 146: ...Index 4 Sun StorEdge A5000 Installation and Service Manual September 1999...