7-26
Sun StorEdge A5000 Installation and Service Manual • September 1999
7.2.12
Removing a Rackmounted Disk Array
Caution –
This procedure requires two people to lift and move the disk array. Use
care to avoid injury. A disk array with a baseplate attached may weigh up to
130 pounds (59 kg).
7.2.12.1
Removing the Chassis From the Cabinet
Follow the instructions on preparing for service in your system or expansion cabinet
documentation. If necessary, be sure to:
■
Extend the antitilt bar
■
Remove or open the top front panel
1. Power off the disk array.
2. Disconnect the power cable.
3. Disconnect the fiber optic cable(s) from the GBICs.
4. Remove the locking screws from the front of the disk array (
Caution –
Always extend a cabinet antitilt bar before removing the locking screws
from the front of the disk array.
FIGURE 7-22
Removing the Screws That Secure the Baseplate to the Side Brackets
Summary of Contents for STOREDGE A5000
Page 12: ...xii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 17: ...Contents xvii D 6 2 sf Driver Software Errors D 15...
Page 18: ...xviii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 22: ...xxii Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 26: ...xxvi Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 38: ...2 6 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 40: ...3 2 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 68: ...5 16 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 76: ...6 8 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 112: ...8 8 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 116: ...A 4 Sun StorEdge A5000 Installation and Service Manual September 1999...
Page 146: ...Index 4 Sun StorEdge A5000 Installation and Service Manual September 1999...