Chapter 5
SAN
Configurations
39
9. Map Logical Drive 1 to channels 1 and 5 of the secondary controller.
10. If more than two logical drives were created, map even-numbered logical drives to
channels 0 and 4 of the primary controller and odd-numbered logical drives to
channels 1 and 5 of the secondary controller.
11. Connect the first switch to port FC 0 of the upper controller and port FC 1 of the
lower controller.
12. Connect the second switch to port FC4 of the lower controller and port FC5 of the
upper controller.
13. Connect each server to each switch.
14. Install and enable multipathing software on each connected server.
15. After completing the configuration, save the configuration using the “Save nvram
to disks” menu option in the firmware application or the “save configuration”
option in Sun StorEdge Configuration Service.
Redundant Point-to-Point SAN
Configurations
FIGURE
5-4
Sample Redundant Point-to-Point SAN Configuration