Sun StorageTek 6140 Array Release Notes, Release 6.2
23
113277-44/README.113277-44
4. Apply the patch with the
patchadd
command.
patchadd 113277-44
5. Reboot your system.
reboot -- -r
Known Issues
The following sections provide information about known issues and bugs filed
against this product release:
■
“Installation and Initial Configuration Issues” on page 23
■
“Hardware and Firmware Issues” on page 25
■
“Documentation Issues” on page 26
■
“Operational Information” on page 28
If a recommended workaround is available for a bug, it follows the bug description.
Installation and Initial Configuration Issues
This section describes known issues and bugs related to installing and initially
configuring the Sun StorageTek 6140 Array.
Auto Code Sync Feature Can Fail During Controller Replacement
Bug 6757957
– Replacement controllers have recently shipped with 7.x version
firmware on them. If the primary controller is replaced while the array is powered
on and a good secondary controller with 06.xx firmware exists, the replacement
should auto code synchronize to the secondary controller. During a controller
replacement the replacement controller occasionally does not auto code synchronize
to the secondary controller as it should. Instead, the array automatically upgrades to
7.x code.
In such a case. the firmware on the controllers will not match the baseline firmware
on the Common Array Manager Software 6.2.0 CD or download. An alarm will be
generated.
Summary of Contents for StorageTek 6140 Array
Page 5: ...Contents v Installing a Tray in a Telco 2 Post Rack 55...
Page 6: ...vi Sun StorageTek 6140 Array Release Notes November 2008...
Page 8: ...viii Sun StorageTek 6140 Array Release Notes November 2008...
Page 42: ...34 Sun StorageTek 6140 Array Release Notes November 2008...
Page 56: ...48 Sun StorageTek 6140 Array Release Notes November 2008...