60
Netra 440 Server Service Manual
• August
2004
System Configuration Card Reader
The system configuration card reader is mounted to the lower piece of the fan tray 3
assembly.
The part number for the system configuration card reader is F540-5856.
Removing the System Configuration Card Reader
Caution –
The system supplies power to the system configuration card reader even
when the system is powered off. To avoid personal injury or damage to the system,
you must disconnect all AC or DC power cables before servicing the system
configuration card reader.
1. Power off the system.
See
“Powering Off the System” on page
.
2. Attach the antistatic wrist strap.
See
“Avoiding Electrostatic Discharge” on page
3. Disconnect the AC or DC power cables from the back of the system.
4. Remove the top cover.
See
“Removing the Top Cover” on page
.
5. Completely remove the system configuration card from the system configuration
card reader.
6. Remove the DVD drive from the front of the system.
See