Sun Fire X4600 to Sun Fire X4600 M2 Server Migration
19
2. Remove the main cover as described in “
“To Remove the Main Cover” on page 11
3. Identify the CPU module or CPU filler board you are replacing.
4. Remove the CPU module or CPU filler board from the bay (see
):
a. Simultaneously rotate both plastic levers on the top corners of the module to
an upright, 90-degree position.
b. Lift the module straight up to remove it from the metal edge-guides in the bay.
Caution –
The pins that connect the CPU module to the motherboard are very
fragile. When you remove the module, rotate both plastic levers at the top corners of
the module simultaneously to avoid jamming the connector pins.
FIGURE 6
Removing a CPU Module From a CPU Module Bay
5. If you are replacing a CPU filler board skip to Step 9.
6. Remove the DIMMs from the CPU module.
a. Rotate both DIMM slot ejectors outward as far as they will go. The DIMM is
partially ejected from the socket. See
.