Sun Microsystems Fire 4800 Product Notes Download Page 7

Product Notes

7

Sun Fire 6800/4810/4800/3800 Systems Platform
Administration Manual Corrections

The Sun Fire 6800/4810/4800/3800 Systems Platform Administration Manual (Chapter
1 page 13) incorrectly states that there are four banks of memory on each CPU bd
and that each bank occupied eight slots. There are actually eight banks of memory
on each CPU/Memory board. Each bank of memory requires a CPU. The CPU is
the MMU (memory management unit). Each bank of memory occupies four slots.

Table 1-10 of the Sun Fire 6800/4810/4800/3800 Systems Platform Administration
Manual 
(Chapter 1 page 17) incorrectly states that the Repeater boards in grid 0
are RP0, RP2 and in grid 1 RP1 and RP3. The correct information is RP0, RP1 for
grid 0 and RP2, RP3 for grid 1.

Known Sun Fire 6800/4810/4800/3800
System Limitations

OBP/POST/System Controller Limitations

ArrayIndexOutOfBound

Error When Powering on/off

Repeater Board From Domain Console (bugid 4411441)

Workaround: Ignore the ’fatal error’ warning message

setkeyswitch on

With An Unknown Log Host Causes Java

Exception (bugid 4411441)

If an invalid loghost name is entered using

setupdomain

in the domain shell and

setupplatform

in the platform shell exceptions will be displayed on the system

controller console (serial port).

Workaround: Rerun

setupdomain -p loghost

in the domain shell and

setupplatform -p loghost

in the platform shell and provide valid loghost

names.

Summary of Contents for Fire 4800

Page 1: ...Alto CA 94303 4900 USA 650 960 1300 Fax 650 969 9131 Sun Microsystems Inc Part No 806 7217 10 March 2001 Revision A Sun Fire 6800 4810 4800 3800 Systems Product Notes Send comments about this documen...

Page 2: ...s Inc 901 San Antonio Road Palo Alto CA 94303 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copi...

Page 3: ...Cabinet Fan Tray Power Switches Documentation Issues Known Sun Fire 6800 4810 4800 3800 System Limitations OBP POST System Controller Limitations Veritas VxVM Limitations Sun Management Center Limitat...

Page 4: ...d Caution Caution To comply with Denmark and Switzerland national requirements customers in these countries who receive a standalone Sun Fire 3800 system shipped without a rack must provide a means to...

Page 5: ...go from low to high speed when either CPU AISC or board temperatures cross 80C 95C and 65C respectively The system is OK and still within the thermal specification when this WARNING message appears F...

Page 6: ...on the right and ending with SB0 on the left Sun Fire 4810 4800 CPU Memory boards are populated from right to left beginning with SB4 on the right and ending with SB0 on the left Sun Fire 3800 system...

Page 7: ...tates that the Repeater boards in grid 0 are RP0 RP2 and in grid 1 RP1 and RP3 The correct information is RP0 RP1 for grid 0 and RP2 RP3 for grid 1 Known Sun Fire 6800 4810 4800 3800 System Limitation...

Page 8: ...unpopulate the memory bank in the lowest numbered CPU board in the domain before booting the Solaris operating environment schostname SC showcomponent sb0 Component Status Pending POST Description N0...

Page 9: ...ly if the configuration database is going to be larger than this it is going to be problem Workaround Create volumes in multiple disk groups when the hard limits on privlen has been reached VxVM_3 1 1...

Page 10: ...tall Does not Recognize SENA T3 Needs License bugid 4413609 Even though SENA exists and is readable vxinstall does not recognize it Workaround Use a temporary VxVM license available through Veritas Su...

Page 11: ...data pertaining to the system controller to get refreshed in the Sun Management Center console Hardware summary information under the Hardware tab in the Platform Details window is not supported SunMC...

Page 12: ...12 Sun Fire 6800 4810 4800 3800 Systems Product Notes March 2001...

Reviews: