2. Remove the plastic cap covering the ends of the fiber cable.
3. Connect one end of the fiber cable into the GBIC module installed on the
interface board rear panel.
Use the IB diagram and GBIC controllers table above to identify the GBIC for the
disk drive. Align the notch in the cable connector with the key notch in the GBIC
module connector. See Figure 2–11.
Figure 2–11
Fiber Cable Ports on the Interface Board
4. Route the fiber cable down toward the bottom of the system, placing it through
the left side restraints on the organizer.
5. Wrap the cable around the fiber cable organizer spools (mounted on the system
rear support bracket) in a “figure 8” pattern as follows:
Cabling the System
23