Figure 2–8
Clock+ Board
2. Connect the terminal power cord into an AC wall outlet.
3. Configure the ASCII terminal as follows:
4
9600 bps
4
1 stop bit
4
8 data bits
4
Parity off
4
Full duplex
Refer to the instruction manual shipped with the terminal for specific
configuration instructions.
Note -
The setup parameters listed in Step 3 on page 19 may differ from the
setup at the customer site. These parameters can be changed in the NVRAM
(nonvolatile random access memory). Refer to the set-defaults and printenv
commands in the OpenBoot Command Reference manual, part number 802-3242.
Cabling the System
19